Справочник Пользователя для Asante Technologies 35516

Скачать
Страница из 77
 
11 
2.3 Gigabit Interface Converters 
 
The GBIC Interface is the industry standard for Gigabit Ethernet Interfaces. Some of the benefits of GBIC 
include reducing the components needed in a “spares” inventory, being able to choose from a wide variety 
of manufacturers with cross-vendor compatibility, and having competitive prices. 
 
Instructions for installing, removing, and maintaining GBIC modules are provided in following sections. 
 
Important! The 35516-G has 12 GBIC ports that are paired— port numbers 1/2, 3/4, 5/6, 7/8, 10/12, and 
14/16. DO NOT use more than one copper GBIC module per pair (maximum 8 modules). 
 
 
 
                   
 
 
Model Part 
Number 
Standard 
Media 
GBIC 1000SX 
99-00549-01 
1000BaseSX  
Multi-mode fiber 
GBIC 1000LX 
99-00550-01 
1000BaseLX  
Single mode fiber 
GBIC 1000T 
99-00673-01 
1000BaseT  
Category 5 UTP (or better) 
copper 
GBIC 1000TP 
99-00647-07 
1000BaseT 
Category 5 UTP (or better) 
copper 
                 Table 2-1 GBIC Modules by Asanté 
 
2.3.1 Installing a GBIC 
 
GBICs are hot-swappable. This means that they can be inserted and removed while the switch is powered 
on. However, please allow 40-60 seconds for the switch to recognize the module when it has been installed 
while the switch is on.  
 
1.  Wearing an ESD (electro-static discharge) wrist strap, remove the GBIC module from its protective 
packaging. 
2.  Verify that the GBIC is the correct type for the network (see the table above). 
3.  Grip the sides of the GBIC with the thumb and forefinger, and then insert the GBIC into the slot on 
the face of the switch. 
4.  Slide the GBIC into the slot until it clicks into place. 
5.  Fiber GBIC modules: Remove the rubber plugs from the end of the GBIC module. Save them for 
future use. 
6.  Attach the appropriate cable. 
 
Note: After installing a GBIC 1000T module, the link LED may light even before a valid cable has been 
connected. This is a normal condition for most 1000BaseT GBIC modules. 
 
Note: Auto-negotiation must be disabled on a port in which a copper GBIC module is installed. Copper 
GBICs themselves control auto-negotiation.