Fault Indications 
If a fault occurs, the following alarm indicators light up, and data transfer may be 
interrupted:  
•  LAN ERR indicator lights when LAN interface indicates an error 
•  LINK ERR indicator lights when LINK interface indicates an error 
•  RED ALARM indicator lights when T1 interface detects red alarm 
•  YELLOW ALARM indicator lights when T1 interface detects yellow alarm 
•  LOC SYNC LOSS indicator lights when the E1 interface detects local sync loss 
•  REM SYNC LOSS indicator lights when the E1 interface detects remote sync 
loss. 
To obtain additional information, observe the state of the other indicators and 
then refer to 
Chapter 6
 for troubleshooting information: 
Turning Off 
Set the FCD-IPM power switch, on the rear panel of the unit, to OFF. 
3.4  Connecting to the ASCII Terminal 
FCD-IPM features a setup program that is invoked and run from an ASCII terminal 
or a PC emulator. The terminal/terminal emulator is connected to the RJ-45 
CONTROL port on the FCD-IPM front panel (see 
Connecting the Terminal Emulator 
 
To connect the terminal emulator: 
1.  Attach the cable to the RS-232 port on the PC. 
2.  Attach the other end of the cable to the CONTROL port on the FCD-IPM front 
panel.