Справочник Пользователя для Huawei MC509

Скачать
Страница из 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Serial Port Control Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
54 
 
5.3.2 Interface Description 
This command sets the changing mode of DSR signals. 
5.3.3 Parameter Description 
<value>: 
0: DSR signals are always ON (default value after startup). 
1: DSR signals are ON after the connection is established (reserved and not 
supported at present). 
 
 
In case of using the command without <value><value> is set to 0
 
5.4 +ICFCommand for Setting the Character Frame 
Format 
5.4.1 Syntax 
Command 
Possible Response(s) 
+ICF[=<format>[,<parity>]] 
<CR><LF>OK<CR><LF> 
In case of an MT-related error: 
<CR><LF>ERROR<CR><LF> 
+ICF? 
<CR><LF>+ICF:<format>[,<parity>]<CR><LF> 
<CR><LF>OK<CR><LF> 
+ICF=? 
<CR><LF>+ICF:(supported <format> list),(supported 
<parity> list) 
<CR><LF> 
<CR><LF>OK<CR><LF> 
 
5.4.2 Interface Description 
This command sets the start and end (asynchronous) frame format of the current 
physical serial port on the MT. This format is used when the MT receives the 
command, information, and result code from the TE. 
At present, only "AT+ICF=3,3" is supported. 
5.4.3 Parameter Description 
<format>: