HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Serial Port Control Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
56 
 
 
 
Automatic detection of the baud rate is not supported at present. Therefore, the first 
returned parameter list is blank when the test command is executed. For example: 
+IPR:(),(300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400) 
 
If the physical serial port baud rate is higher than the radio bearer rate, data may be lost 
when being transmitted. 
 
After the baud rate is changed, wait for a period of time (for example, 100 ms) before 
continuing the communication. 
 
5.5.3 Parameter Description 
<rate>: Specifies the baud rate. It is a decimal integer. The values are as follows: 
300,600,1200,2400,4800,9600,19200,38400,57600,115200,230400 
 
 
AT+IPR without a parameter is equivalent to AT+IPR=115200
 
5.6 +IFCCommand for Setting Flow Control 
5.6.1 Syntax 
Command 
Possible Response(s) 
+IFC[=<DCE_by_DTE>
 
[,<DTE_by_DCE>]] 
<CR><LF>OK<CR><LF> 
In case of an MT-related error: 
<CR><LF>ERROR<CR><LF> 
+IFC? 
<CR><LF>+IFC:<DCE_by_DTE>,<DTE_by_DCE><
CR><LF> 
<CR><LF>OK<CR><LF> 
+IFC=? 
<CR><LF>+IFC:(supported <DCE_by_DTE> list), 
(supported <DTE_by_DCE> list)<CR><LF> 
<CR><LF>OK<CR><LF> 
 
5.6.2 Interface Description 
This command sets and queries bidirectional flow control. 
5.6.3 Parameter Description 
<DCE_by_DTE>: 
0: none (default value after startup)