F l a g s
Flags show the status of an event or condition.  A flag will only have one of two possible states: either 1 or 0. Unlike variables,
there are only factory defined flags.
F a c t o r y   D e f i n e d   F l a g s
Factory defined flags are predefined at the factory and cannot be deleted. When a FD (Factory Defaults) instruction is given, these
flags will be returned to their factory default state.  There are two types of factory defined flags:
.
Read/Writable: This type of flag is user alterable.  They are typically used to set a condition or mode of operation
for the MDrive Motion Control. For example: EE = 1 would enable encoder operation, or EE = 0 would disable the
encoder functions.
.
Read Only: Read Only flags cannot be modified by the user. They only give an indication of an event or condition.
Typically this type of flag would be used in a program in conjunction with the BR (Branch Instruction) to generate
an if/then event based upon a condition. For Example: the following line of code in a program  BR SP,  MV = 0
would cause a program to branch to a subroutine named “SP” when the MV, the read only moving flag, is false.
K e y w o r d s
Keywords are used in conjunction with the PR and IP instructions to indicate or control variables and flags.  For instance, PR UV
would print the state of all the user-defined variables to the screen. IP would restore all the factory variables from the EEPROM.
M o s t   C o m m o n l y   U s e d   V a r i a b l e s   a n d   C o m m a n d s
V a r i a b l e s
P
P indicates the position in either steps or encoder counts depending upon the enable/disable state of encoder functions.
.
P takes its reading from C1 (Counter 1) when encoder functions are disabled. The reading is taken from C2 (Counter 2) when
encoder functions are enabled.
.
To read the position, type PR P or PR C1/C2 then hit enter
.
To zero the position, type P=0  then hit enter
V I
Initial velocity in steps per second.
.
To read the initial velocity, type PR VI then hit enter
.
To write to the Initial velocity, type VI=500  then hit enter
V M
Maximum or final velocity in steps per second.
.
To read the final velocity, key-in PR VM then hit enter
.
To write to the final velocity, key-in VM=5000  then hit enter
A
Acceleration in steps per second
2
.
.
To read the acceleration, key-in PR A then hit enter
.
To write to the acceleration, key-in A=7500  then hit enter
D
Deceleration in steps per second
2
.
.
To read the deceleration, key-in PR D then hit enter
.
To write to the deceleration, key-in D=A then hit enter