3   SPECIFICATION 
MELSEC-QnA 
 
(2)   Data link status at host station: Xn1 
Indicates data link status at the host station. 
SB006E represents the same meaning. For programming, use either Xn1 or 
SB006E. 
Note that the ON/OFF condition for Xn1 is opposite to that for SB006E. 
When Xn1 is used, the condition is as follows: 
OFF  : data link stopped 
ON  : data link in progress 
 
Initialization
Start processing
OFF
OFF
Power ON
0
Data link status at host station 
(Xn1)
Parameter setting status
(Xn2)
Host parameter status
(SW0068)
Data link startup request from 
buffer memory/E PROM 
Parameter  (Yn6/Yn8)
Module ready 
(XnF)
Module error
(Xn0)
Module reset acceptance 
complete (Xn4)
Module reset request
(Yn4)
Data link startup by buffer 
memory/E PROM parameter 
normal completion (Xn6/Xn8)
2
2
 
 
(3)   Parameter setting status: Xn2 
Indicates parameter setting status at host station. 
SB006D represents the same meaning. For programming, use either Xn2 or 
SB006D. 
OFF : normal 
ON  : error in setting (An error code is stored in SW0068.) 
Turns off when Yn6 or Yn8 is executed in the status that error does not 
occur.