10.2 Creating a Program 
10.2.1 Program for parameters 
This program automatically initiates the data link when the programmable controller 
CPU starts running. 
 
[When debugging] 
 
X0040 X004F
PLS M300
M300
SET M301
M301
K2
D0
MOV
K7
D1
MOV
K1
D2
MOV
D0
K3
TO
H0004 H0001
K0
D3
MOV
D3
K1
TO
H0004 H0006
M301
H1201
D4
MOV
H1203
D5
MOV
D4
K2
TO
H0004 H0020
M301
RST
Station information
Number of connected
modules 
Number of retries 
Number of automatic
return modules
Operation specification  
when the CPU goes
down (stop) 
AJ65BT- 64AD
(station No.1) 
AJ65BT- 64DAV
(station No.3) 
Parameter 