Справочник Пользователя для Mitsubishi Electronics A1SJ61QBT11

Скачать
Страница из 294
 
 
 
10 - 5 
10   COMMUNICATION BETWEEN THE MASTER STATION AND THE 
REMOTE DEVICE STATION 
MELSEC-QnA 
 
X0040 X004F
PLS
M302
M302
SET
M303
M303
SM402
SET
Y40
SET
Y46
X0046
RST
Y46
RST
M303
X0047
RST
Y46
RST
M303
D100 K1
FROM H0004 H0668
X0040 X004F
PLS
M304
M304
SET
M305
M305
SET
Y4A
X004A
RST
Y4A
RST
M305
X004B
RST
Y4A
RST
M305
D101 K1
FROM H0004 H06B9
Data link by the 
parameters 
in the buffer memory 
 
Registering parameters  
to E
2
PROM 
 
 Refresh instruction
 
When the data link 
startup is completed 
normally by the 
parameters in the  
buffer memory 
 
When the data link 
startup is completed  
fault by the  
parameters in the  
buffer memory 
 
PROM 
When parameter  
registration to E
2
is completed normally 
 
When parameter 
registration to E
2
PROM 
is completed fault
Register  
command
: Refer to Section 8.2 when using the software version E (manufactured in Aug., 2001) or later of the A1SJ61QBT11.