2 - 5 
2   SYSTEM CONFIGURATION 
MELSEC-QnA 
 
POINT 
 
To utilize the functions described in Chapter 14 or later, use a module with "9707B*" or later is 
shown as a DATE code on the rating plate. 
* "9707B" indicates that the module was manufactured in July 1997 and its function version is 
B. 
 
PROGRAMMABLE CONTROLLER
BD992C103H06
DATE
MADE IN JAPAN
MODEL
POWER
DATE
MADE IN JAPAN
BD992C154H06
0512    B
0512   B
Manufactured
date
Function
version
Manufactured
date
Function
version
 
 
 
(3)   Access to station No.64 
(a)    To a local station of No. 64, other station access from GX Developer or 
GOT is not allowed. 
If the station No. is changed to other than 64, other station access is 
executable. 
(b)  The CC-Link board is not allowed to access a local station or intelligent 
device station whose station No. is 64. 
If the station No. is changed to other than 64, other station access is 
executable. 
 
(4)   Precautions for use on remote I/O stations 
Transient transmissions using dedicated instructions are not allowed to local 
stations and intelligent device stations.