Справочник Пользователя для Mitsubishi Electronics FX

Скачать
Страница из 382
FX Series Programmable Controller
Diagnostic Devices 6
6-8
6.7
Error Detection Devices
(M8060 to M8069 and D8060 to D6069) 
Diagnostic
Device
Operation
Diagnostic
Device
Operation
Detection
PROG.E
LED
PLC
STATUS
M8060 (
)
I/O configura-
tion
error
(Not FX
0(S)
FX
0N
)
While the 
PLC is in 
RUN
OFF
RUN
D8060 (
)
(Not FX
0(S)
FX
0N
)
The first I/O number of the unit 
or block causing the error - 
See note 3
M8061 (
)
PLC hardware
error
Flash
STOP
D8061 (
)
Error code for hardware error - 
See also appropriate PLC 
hardware manual
M8062 (
)
PC/HPP
communication
error
(Not FX
0(S)
FX
0N
)
When a 
signal from 
the HPP is 
received
OFF
RUN
D8062 (
)
(Not FX
0(S)
FX
0N
)
Error code for PC/HPP Com-
munications error -See appro-
priate error code table
M8063(
)(
R)
Parallel link/
ADP error
(Not FX
0(S)
FX
0N
)
When 
paired sta-
tions sig-
nal is 
received or 
ADP com-
munica-
tions are in 
error
D8063(
)(
-
R)
(Not FX
0(S)
FX
0N
)
Error code for parallel link 
error - See also hardware 
manual. Also identification of 
ADP communication 
error - See also FX-485PC-IF 
users manual
M8064 (
)
Parameter
error
When the 
program is 
changed 
(PLC in 
STOP) and 
when a 
program is 
transfer-
red (PLC in 
STOP)
Flash
STOP
D8064 (
)
Error code identifying parame-
ter error - See appropriate 
error code table
M8065 (
)
Syntax error
D8065 (
)
Error code identifying syntax 
error - See appropriate error 
code table
M8066 (
)
Program
error
D8066 (
)
Error code identifying program 
construction error
See appropriate error code 
table
M8067(
)(
R)
Operation
error
While in 
PLC is in 
RUN
OFF
RUN
D8067(
)(
R)
Error code identifying opera-
tion error. See appropriate 
error code table
M8068 (
)
Operation
error latch
D8068 (
)
Operation error step number 
latched
M8069 (
)
I/O bus error
(Not FX
0(S)
FX
0N
)
See note 4 -
-
D8069(
)(
R)
Step numbers for found errors 
corresponding to flags M8065 
to M8067
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)