FX Series Programmable Controllers
Assigning System Devices 9
9-5
9.2.4
Using the FX
2
-24EI With A F
2
-30GM
The F
2
-30GM’s operational address is based upon the position of the associated FX
2
-24EI
within the users FX system. However, the I/O numbers are not directly affected by this
operational address. The I/O numbers can be selected by the user. The diagram on the page
9-3 shows how moving the position of the FX
2
-24EI used alters the operational address but
NOT the I/O numbers used by the F
2
-30GM, see EX. 2A to 2C. Where the symbol § is used in
the diagram, this can be replaced by the numbers ‘0’, ‘4’ or ‘5’. It is recommended that for
simplification the user favors ‘0’.
For details on using the F
2
-30GM see the units users manual. Please remember when reading
the manual, that it has been written for use on an F
2
 system and hence all of the I/O addresses
stated are for such an F
2
 setup.
Worked example:
The following tabular example identifies the correspondence between FX and F
2
-30GM
systems.
The FX system used is similar to that shown in the diagram EX. 2B from page 9-3.
Applicable FX Applied Instructions:
(Not applicable to FX
2C
 Main Processing Units or FX units with CPU’s greater than version
3.06)
• FNC 97, BLK - used to designate a block number within the F
2
-30GM
FNC 98, MCDE - used to read an M code number from the F
2
-30GM
F2-30GM System Setup
Comments
FX System Setup
X
14 to X
27
Turn On 
X54 to X67
Y
40 to Y
47
Are Turned On BY 
Y40 to Y47
X0 to X6
No correspondence
N/A
Y0 to Y6
No correspondence
N/A
FX
0(S)
FX
0N
FX FX
(2C)
FX
2N(C)