Timer Interface B (TIMB)
 241
12.8.3  TIMB Counter Modulo Registers
The read/write TIMB modulo registers contain the modulo value for the 
TIMB counter. When the TIMB counter reaches the modulo value, the 
overflow flag (TOF) becomes set, and the TIMB counter resumes 
counting from $0000 at the next clock. Writing to the high byte 
(TBMODH) inhibits the TOF bit and overflow interrupts until the low byte 
(TBMODL) is written. Reset sets the TIMB counter modulo registers.
NOTE:
Reset the TIMB counter before writing to the TIMB counter modulo 
registers.
Register Name and Address: TBMODH — $0054
Bit  7
6
5
4
3
2
1
Bit  0
Read:
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Write:
Reset:
1
1
1
1
1
1
1
1
Register Name and Address: TBMODL — $0055
Bit  7
6
5
4
3
2
1
Bit  0
Read:
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Write:
Reset:
1
1
1
1
1
1
1
1
Figure 12-6. TIMB Counter Modulo Registers