10
 
S1-5 and S1-6:  Clock Source
 
Switches S1-5 and S1-6 are set in combination to determine the transmit 
clock source for the Model 1080ARC (see Table 3).
 
S1-7:  Asynchronous/Synchronous Mode
 
The setting for switch S1-7 determines whether the Model 1080ARC is in 
asynchronous or synchronous operating mode (see Table 4).
 
S1-8:  Carrier Control Method
 
The setting for switch S1-8 determines whether the carrier is “constantly 
on” or “controlled by RTS”.  This setting allows for operation in switched 
carrier, multipoint and/or hardware handshaking applications (see 
Table 5).
 
Table 3: 
 
S1-5 and S1-6: Clock Source Settings
 
S1-5
S1-6
Setting
 
On
On
Internal transmit clock
Off
On
Receive recover clock
On
Off
External transmit clock
 
Table 4: 
 
Asynchronous/Synchronous Mode Settings
 
S1-7
Setting
 
On
Asynchronous
Off
Synchronous
 
Table 5: 
 
Carrier Control Method Settings
 
S1-8
Setting
 
Off
Constantly on
On
Controlled by RTS