Patton electronic 1080ARC 用户手册

下载
页码 40
 
9
 
3.2  CONFIGURATION SWITCH SET “S1”
 
The DIP switches on S1 set data rate, clock source, async./sync. mode 
and carrier control method.  The default settings are summarized in 
Table 1.
 
S1-1 through S1-4:  Data Rate Setting
 
Switches S1-1 through S1-4 are set in combination to determine the 
asynchronous and synchronous data rate for the Model 1080ARC (see 
Table 2).
 
Table 1: 
 
Summary of DIP switch default settings for set S1
 
Position
Function
Factory Default
 
S1-1
Data Rate
On
9,600 bps
S1-2
Data Rate
Off
9,600 bps
S1-3
Data Rate
Off
9,600 bps
S1-4
Data Rate
On
9,600 bps
S1-5
Clock Source
On
Internal
S1-6
Clock Source
On
Internal
S1-7
Async./Sync.
On
Async.
S1-8
Carrier Control
Off
Constantly On
 
Table 2: 
 
S1-1 through S1-4: Data Rate Settings
 
S1-1
S1-2
S1-3
S1-4
Setting
 
On
On
On
On
1.2 kbps
Off
On
On
On
1.8 kbps
On
Off
On
On
2.4 kbps
Off
Off
On
On
3.6 kbps
On
On
Off
On
4.8 kbps
Off
On
Off
On
7.2 kbps
On
Off
Off
On
9.6 kbps
Off
Off
Off
On
14.4 kbps
On
On
On
Off
19.2 kbps
Off
On
On
Off
28.8 kbps
On
On
Off
Off
38.4 kbps
Off
On
Off
Off
57.6 kbps