Roland AR-200 用户手册

下载
页码 72
 
32
Controlling the AR-200 from an External Device (Control Input Connectors)
 
Operational Specifications of 
Binary Playback
 
Basic Operation of Binary Playback
 
fig.inp-16
 
Playback:
Specify the phrases using combinations of 0 (Off) and 1 (On) 
signals to Port Nos. 1 through 8, and Port Nos. 11 and 12, and 
input a control signal to the Port No. 9 (START).
 
 
 This plays back the specified phrase.
Stopping:
Input a control signal to Port No. 10 (STOP).
 
 
 This stops playback of the phrase.
The basic operation of Binary Playback is shown below.
 
fig.inp-17
 
Binary specified phrases are played back repeatedly.
Playback is repeated while the start signal is continuously 
input.
You can begin playback of phrases by specifying phrases in 
binary with the start signal continuously being input.
When the START connector control signal switches to Off, 
the current phrase finishes, and then playback is stopped.
No action results when a new start signal is input while a 
phrase is being played back.
 
AR-200 Settings
 
Selecting the Control Input Mode
 
Set the MODE switches on the AR-200’s bottom panel to 
select “BINARY PLAYBACK” from the control input modes 
(PLAYBACK BY CARD DATA/DIRECT PLAYBACK/
BINARY PLAYBACK/INTERVAL PLAYBACK).
 
* You cannot achieve control input playback merely by 
connecting a device to the port. Be sure to set the control input 
mode and match the method used for connecting to the 
connectors.
 
Procedure for Setting the Control Input Mode
 
1.
 
Turn off the power of the AR-200.
 
2.
 
Set the MODE switches on the AR-200’s bottom panel as 
shown below.
SW1: OFF
SW2: ON
 
3.
 
Turn on the power of the AR-200.
 
* Use a pointed object to change the ON/OFF settings of the 
MODE switches.
 
To Specify Phrases with Binary 
Signals
 
Example: Specifying Phrase 0112 (Phrase #: 0112)
 
1.
 
Convert the phrase number to a binary signal number.
”0” (Off)
”1” (On)
 
Phrase Number/Binary Signal Correspondence Table (p. 36)
The phrase number “0012” becomes the binary signal 
“01110000.”
With the above step, Phrase No. 0112 is converted to:
 
fig.inp-18
 
Input of binary specifications should be completed in no 
more than 50 milliseconds.
AUDIO OUTPUT
Binary Specification
Port No.1--8
START Port
0001
0001
AUDIO OUTPUT
Binary Specification
Port No.1--8
START Port
0001
0001
0002
Disabled
0002
0001
0003
0003
   8   7   6   5   4   3   2   1   
   0   1   1   1   0   0   0   0
Phrase Number (Binary)
Port No.
INPUT Signal
AR-200_e.book 32 ページ 2003年7月14日 月曜日 午後1時11分