Controlling the AR-200 from an External Device (Control Input Connectors)
 
Repeated Playback of 
 
Phrases (Interval Playback)
 
The specified phrase will be played back at fixed intervals. 
Make each of the terminal settings beforehand for the 
playback interval and phrases to be played back.
When making settings in Interval Playback mode, assign 
Phrases 1 through 9 to the control output connectors 1 
through 9.
The playback interval settings are shown below.
Port No.
Playback Interval
1
1 second
2
5 seconds
3
10 seconds
4
15 seconds
5
30 seconds
6
1 minute
7
5 minutes
8
15 minutes
9
30 minutes
 
Operational Specifications of 
Interval Playback
 
Basic Operation of Interval Playback
 
fig.inp-21
 
[Interval time used for phrases]
Playback:
Input control signals to the control Input/output connectors 
No. 1 through 9.
 
 →
 
 Results in the repeated play of the phrase assigned to the 
terminal.
stopping:
Input a control signal to Port No. 10 (STOP).
 
 →
 
 This stops playback of the phrase.
 
AR-200 Settings
 
Selecting the Control Input Mode
 
Set the MODE switches on the AR-200’s bottom panel to 
select “INTERVAL PLAYBACK” from the control input 
modes (PLAYBACK BY CARD DATA/DIRECT 
PLAYBACK/BINARY PLAYBACK/INTERVAL 
PLAYBACK).
You cannot achieve control input playback merely by 
connecting a device to the port. Be sure to set the control 
input mode and match the method used for connecting to the 
connectors.
 
Procedure for Setting the Control Input Mode
 
1.
 
Turn off the power of the AR-200.
 
2.
 
Set the MODE switches on the AR-200’s bottom panel as 
shown below.
SW1: ON
SW2: ON
 
3.
 
Turn on the power of the AR-200.
 
* Use a pointed object to change the ON/OFF settings of the 
MODE switches.
 
Controlling Recording with 
the Control Connectors 
 
(Terminal Rec)
 
What is Terminal Rec/Use and 
Applications
 
You can specify phrases by inputting binary (base 2) signals 
to the Port Nos. 1 through 8, and perform record, playback, 
and erase functions by inputting control signals to Port Nos. 
9 and 10. A total of 250 phrases can be specified with control 
signals (On/Off). This is convenient when you want to 
control recording from an external control device.
 
fig.inp-22
 
[Signal sent to Port Nos. 9 and 10]
 
* To conduct binary control, you need to provide a control 
device that can generate binary signals.
* Input of binary specifications should be completed in no more 
than 50 milliseconds.
0002
AUDIO OUTPUT
Port No. 2
STOP Port
0002
0002 interrupted
Interval time used for phrases
Binary Specification
01110000
Phrase112
Record
Play
Delete
8 7 6 5 4 3 2 1
Signal sent to Port 
Nos. 9 and 10
Port 1--8
AR-200_e.book 34 ページ 2003年7月14日 月曜日 午後1時11分