Roland AR-3000R 用户手册

下载
页码 152
 
15
Panel Descriptions
 
8. LINE IN Jack
 
This is used when recording audio from a device equipped with 
an analog audio-output jack.
 
9. Audio Output Jacks (BALANCED OUTPUT)
 
These are the final audio output jacks. They are used for 
connection to a power amp or the like. Both balanced and 
unbalanced connections are possible.
 
922
 
* This instrument is equipped with balanced (TRS) type jacks. 
Wiring diagrams for these jacks are shown below. Make 
connections after first checking the wiring diagrams of other 
equipment you intend to connect.
 
fig.2-05e
 
926a
 
When connection cables with resistors are used, the volume 
level of equipment connected to the inputs (LINE IN Jack) 
may be low. If this happens, use connection cables that do 
not contain resistors, such as those from the Roland PCS 
series.
 
10. Option Board Slot
 
This is the recess for installing an option board.
 
 
 “Installing an Option board” 
 
When installing, be sure to refer to the owner’s manual for 
the option board.
 
11. Option Board Space
 
This is where an option board is installed.
 
 
 “Installing an Option board”
 
When installing, be sure to refer to the owner’s manual for 
the respective option board.
 
12. Rubber Feet (Included Items)
 
 
 
Installing an Option Board
 
When installing, be sure refer to the owner’s manual for the 
respective option board.
 
fig.2-06e
 
Important Notes on Installation
 
 
  Before installing the board, switch off the power to the 
equipment and unplug the power cord from the power outlet.
 
 
  Remove only the specified screws.
 
 
  Be careful not to let removed screws fall into the unit.
 
 
  After you have removed the panel, cover, and screws, do not 
leave them off. When you have finished installing the option 
board, be sure to reattach the panel, cover, and screws.
 
 
  Be careful not to cut your hand on the opening for installing the 
board.
 
 
  After installation, if the unit fails to power up when you switch 
on the power, contact your Roland Service Station.
 
● 
 
To avoid the risk of damage to internal components that can be 
caused by static electricity, please carefully observe the 
following whenever you handle the board.
 
 
Before you handle the circuit board, first touch the front panel 
of the AR-3000R, and while maintaining contact with the front 
panel, pick up the circuit board. This discharges any static 
electricity that has accumulated in your body and clothing.
 
 
When handling the board, grasp it only by the panel or the 
board’s edges. Avoid touching any of the electronic 
components or connectors.
 
 
When handling the board, grasp it only by the panel or 
the board’s edges. Avoid touching any of the electronic 
components or connectors.
 
 
Before you connect any cables, make sure they do not 
carry a static electricity charge. Such charges can be 
GND(SLEEVE)
HOT(TIP)
COLD(RING)
Balanced Output
GND(SLEEVE)
HOT(TIP)
Unbalanced Output
Rear Panel
Top Panel
Removed screws
Option board
 
901
AR-3000R_e.book 15 ページ 2010年3月18日 木曜日 午後2時6分