Dynatech PN 106082: 115v 用户手册

下载
页码 46
ITW Dynatec c. 1999 
 
Page 2 - 7 
TPC-2 TIMER Manual #50-05 
 
Revised 11/04 
230VAC Power Cord Wiring 
 
WIRE COLOR 
DESIGNATION 
Brown or Black 
Power (+) 
Blue or White 
Neutral (-) 
Green Ground 
CAUTION: Avoid the installation of input or output cords near or parallel to 
power lines from other machinery. The resulting electrical “noise” can produce 
adverse effects on the TPC-2 Control Unit which could result in unreliable 
operation. 
Receptacle Assignments 
Below are the pin assignments for the input/output receptacles located at the bottom of 
the TPC-2 Control Unit. 
 
 
P
IN 
A
SSIGNMENT
 
R
ECEPTACLE
 
1 2 3 4 5 6 7 8 9 
D
RIVE 
 
 
 
 
minus 
+16V
DC 
 
 
 
D
RIVE 
 
 
 
 
minus 
+16V
DC 
 
 
 
A.T.S. 
 
 
 
 
minus 
+16V
DC 
 
 
 
T
RIGGER
 
+12V
DC
 
Gnd 
Signal 
(NPN)
 
Chas-
sis 
Gnd 
NOTE: shorting pins #2 & #3 will    
manually initiate the trigger. 
P
URGE
 
 - 
minus 
+12V
DC 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
cont.
 
 
Drive 1
Drive 2
Trigger
ATS
Purge
1
2
3
4
5
6
7
8
9
1
2
3
4