Dynatech PN 106082: 115v 用户手册
ITW Dynatec c. 1999
Page 2 - 7
TPC-2 TIMER Manual #50-05
Revised 11/04
230VAC Power Cord Wiring
WIRE COLOR
DESIGNATION
Brown or Black
Power (+)
Blue or White
Neutral (-)
Green Ground
CAUTION: Avoid the installation of input or output cords near or parallel to
power lines from other machinery. The resulting electrical “noise” can produce
adverse effects on the TPC-2 Control Unit which could result in unreliable
operation.
power lines from other machinery. The resulting electrical “noise” can produce
adverse effects on the TPC-2 Control Unit which could result in unreliable
operation.
Receptacle Assignments
Below are the pin assignments for the input/output receptacles located at the bottom of
the TPC-2 Control Unit.
the TPC-2 Control Unit.
P
IN
A
SSIGNMENT
R
ECEPTACLE
1 2 3 4 5 6 7 8 9
D
RIVE
1
-
minus
+16V
DC
D
RIVE
2
-
minus
+16V
DC
A.T.S.
-
minus
+16V
DC
T
RIGGER
+12V
DC
Gnd
Signal
(NPN)
Chas-
sis
Gnd
NOTE: shorting pins #2 & #3 will
manually initiate the trigger.
P
URGE
-
minus
+12V
DC
cont.
Drive 1
Drive 2
Trigger
ATS
Purge
1
2
3
4
5
6
7
8
9
1
2
3
4