Whirlpool W10388779A-SP 用户手册

下载
页码 36
11
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best 
for your installation. Two close-clearance installations are shown. 
Refer to the manufacturer’s instructions.
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible 
portion of mobile home and must not terminate beneath the 
mobile home. Terminate exhaust vent outside. 
Moblie Home Exhaust installation
A
B
  
 
 
A. Over-the-top installation  
 
 
 
    (also available with one offset elbow) 
 
 
 
B. Periscope installation
NOTE: The following kits for close clearance alternate 
installations are available for purchase. Contact your local dealer.
Over-the-Top Installation: 
 
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent 
 
mismatch): 
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
         Part Number 4396011 - 18" (460 mm) to 29" (737 mm)  
mismatch
       Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)  
 
 mismatch
Determine vent length and elbows needed for best 
drying performance:
Use following Vent System Chart to determine type of vent 
 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified  
in Vent System Chart. Exhaust systems longer than those 
specified will:
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
 
and increased energy usage.
Whirlpool Vent System Chart
Number of 
90° elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent System Charts provide venting requirements that 
will help achieve best drying performance.
NOTE: Bottom exhaust installations have a 90° turn inside the 
dryer. To determine maximum exhaust length, add one 90° turn 
to the charts.
Maytag Vent System Chart
Number of 
90° elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
71 ft. (21.6 m)
63 ft. (19.2 m)
94 ft. (28.7 m)
84 ft. (25.6 m)
74 ft. (22.6 m)
65 ft. (19.8 m)
57 ft. (17.4 m)
Determine vent path:
Select route that will provide straightest and most direct  
 
path outdoors.
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
 
as possible.
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.