Whirlpool W10388779A-SP 用户手册

下载
页码 36
12
CONNECT INLET HOSES 
 
For non-steam models, skip to “Connect Vent” on page 14.
 
 
The dryer must be connected to the cold water faucet using  
the new inlet hoses. Do not use old hoses.
Turn cold water off, remove and 
replace rubber washer
1. 
Turn cold water faucet off and remove washer inlet hose.
Check and see if rubber washer is in the “Y” connector. 
Remove old rubber washer from inlet hose and replace with 
new rubber washer provided. 
Open shut-off valve
 3.
Open shut-off valve in supply line; valve is open when handle 
is parallel to gas pipe. Then, test all connections by brushing 
on an approved noncorrosive leak-detection solution. 
Bubbles will show a leak. Correct any leaks found.
A
 Open valve 
Closed valve
A
B
C
D
Plan pipe fitting connection
 2.
A combination of pipe fittings must be used to connect dryer 
to existing gas line. A recommended connection is shown. 
Your connection may be different, according to supply line 
type, size, and location.
A. 3/8" flexible gas connector
B. 3/8" dryer pipe 
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
Connect vent to exhaust hood
2.
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location 
using straightest path possible. Avoid 90° turns. Use clamps 
to seal all joints. Do not use duct tape, screws, or other 
fastening devices that extend into interior of vent to secure 
vent, because they can catch lint.
INSTALL vENT SYSTEM
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal 
exterior wall opening around exhaust hood.
Connect gas supply to dryer
 1.
Remove red cap from gas pipe. Using a wrench to tighten, 
connect gas supply to dryer. Use pipe-joint compound  
on threads of all non-flared male fittings. If flexible metal  
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to action of LP gas. Do not use  
TEFLON
®†
 tape.
MAKE GAS CONNECTION
A
B
Non-flared  
male fitting
Flared  
male fitting
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.