B&K 8510 用户手册

下载
页码 57
 
14
LOAD CURRENT
LOAD INPUT 
VOLTAGE
I
V
VOLT 
SETTING
CONSTANT VOLTAGE MODE
 
 
Constant Power (CW) Mode 
In this mode, the electronic load’s power consumption will be in accordance with the programmed value, regardless of the 
input voltage. The CW mode can be set with front panel keys. The CW mode parameters are discussed in the following 
paragraphs. 
 
LOAD 
CURRENT
LOAD INPUT 
VOLTAGE
I
V
POWER 
SETTING
CONSTANT POWER  MODE
V2
V3
I2
I2
I2
I2
I3
I3
I3
I3
 
Transient Operation 
Transient operation enables the electronic load to periodically switch between two load levels, as might be required for 
testing power supplies. A power supply's regulation and transient characteristics can be evaluated by monitoring the supply's 
output voltage under varying combinations of load levels, frequency, and duty cycle. 
Transient operation can be turned on and off at the front panel or via PC control using the IT-E131 isolated communication 
cable. Before turning on transient operation, you should set the desired mode of operation as well as all of the parameters 
associated with transient operation. Transient operation may be used in the CC, CR, or CV or CW modes and can be setup 
in continuous, pulsed, or toggled operation mode. 
Continuous 
Generates a repetitive pulse stream that toggles between two load levels and changes the state between value A and 
value B.