B&K 8510 用户手册
35
Steps:
1) Press
Shift
+
Menu
to enter into menu, VFD displays
>CONFIG
2) Press
Enter
into the submenu, VFD displays
>INITIAL CONFIG
3) Press▼to make VFD display
RANGE SELECT
4) Press
Enter
to confirm, and press▼to choose
ON
5) Press
Enter
to confirm
6) Press
ESC
to exit menu
Voltage range: Now you can press
+▲ to switch from the maximum range to the lower range and high
resolution. If the former maximum voltage value was 120V with a resolution of 10mV, it will change to 18V range/
1mV resolution when pressing
1mV resolution when pressing
+▲ , and the display will show 3 decimal points (xx.xxx) as opposed to 2
decimal points. If the former maximum voltage was 18V, you can press
+▼ to set the instrument to 120V
range, with this setting the resolution will change accordingly to 10mV.
Current range: Press
Current range: Press
+▼ to select the maximum current range. If the former maximum current value is
12A and the resolution is 1mA, it will now be set to 120A max/10mA resolution. By pressing
+▼, you
will get 2 decimal points (xx.xx) compared to 3 decimal points. To toggle from the 120A to the 12A range, press
+▲, now the resolution will be set to 1mA.
Specifications
Parameter
8510
Voltage 0
to
120V
Current 1mA
to120A
Input rating
Power 600
W
Range
Accuracy
Resolution
0-18V
±(0.05%+0.02%FS)
1mV
0-120V
±(0.05%+0.025%FS)
10mV
0-12A
±(0.1%+0.1%FS)
1mA
Load
Regulation
0-120A
±(0.2%+0.15%FS)
10mA
0.1-18V ±(0.05%+0.02%FS)
1mV
CV Mode
Regulation
0.1-120V ±(0.05%+0.025%FS)
10mV
0-12A
±(0.1%+0.1%FS)
1mA
CC Mode
Regulation
0-120A
±(0.2%+0.15%FS)
10mA
0.1 -10Ω ±(1%+0.3%FS)
0.001Ω
10-99Ω ±(1%+0.3%FS)
0.01Ω
100-999Ω ±(1%+0.3%FS)
0.
1Ω
CR Mode Regulation
Input current ≥FS 10%
Input Voltage≥FS 10%
1K-4KΩ ±(1%+0.8%FS)
1Ω