Omron FQM1-MMP21 用户手册

下载
页码 414
111
Synchronous Data Refresh
Section 5-4
Note
(1) Addresses are the same for the Coordinator Module and all Motion Con-
trol Modules.
(2) When the synchronous data is one-word data (analog input values, ana-
log output values, built-in I/O, etc.), the other word can be used for gen-
eral-purpose data.
5-4-4
Settings
The following settings must be made beforehand when using the synchronous
data refresh function.
System Setup 
(Coordinator Module)
Synchronization between Modules and Sync Cycle Time must be set in the
Coordinator Module's System Setup.
Synchronization between Modules
Sync Cycle Time 
When the Sync Cycle Time is specified, all Motion Control Modules will syn-
chronize with the Coordinator Module cycle time in PROGRAM mode. The
specified Sync Cycle Time is enabled in RUN and MONITOR modes, and the
Motion Control Module cycle times will change to the set Sync Cycle Time
when in these modes.
Synchronous data link bits will be broadcast from each Module at the time
specified under Sync Cycle Time.
If an interrupt task 000 is created, it can be used as a regular interrupt task
executed each Sync Cycle Time.
When the Sync Cycle Time is on the default setting, the synchronous data link
bits are broadcast from each Module each Coordinator Module cycle. The
Motion Control Module cycles are synchronous with the Coordinator Module
cycle.
Note
If the Sync Cycle Time Too Long Flag (A404.06) turns ON in the Coordinator
Module, it means that the Motion Control Module cycle time is longer than the
Sync Cycle Time. Either change the Sync Cycle Time or check the Motion
Control Module ladder program and shorten the Motion Control Module cycle
time to less than the Sync Cycle Time.
Sent from Motion 
Control Module #4
CIO 0216
00 to 15
Set using upper 2 words of Select Synchronous Data in the System 
Setup for Motion Control Module #4.
CIO 0217
00 to 15
CIO 0218
00 to 15
Set using lower 2 words of Select Synchronous Data in the System 
Setup for Motion Control Module #4.
CIO 0219
00 to 15
Synchronous Data 
Link Bit Areas in 
Coordinator and 
Motion Control 
Modules
Word 
address 
(See note 
1.)
Bits
Method for selecting type of synchronous data
Name
Settings
Default
Description
Auxiliary Area 
Flags
Enabled
Module Settings Tab Page
Sync Mode
Sync/Async
Sync
Synchronization 
between Modules
---
At power ON
Name
Settings
Default
Description
Auxiliary Area 
Flags
Enabled
Module Settings Tab Page
Sync Cycle Time
Default (cycle time) 
(0.1 to 10.0 ms)
CM cycle time
Sync cycle time 
(unit: 0.1 ms)
A404.06 
Sync Cycle Time 
Too Long Flag
At power ON