Magellan MG-6060 用户手册

下载
页码 48
22
Reference & Installation Manual
Alarm Options
Bell Cut-off Timer
Section [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 
minutes
After an audible alarm, the siren will stop upon disarming of the 
system or when the Bell Cut-Off timer has elapsed, whichever 
comes first.
Wireless Transmitter Supervision Options
Section [094]: Options [6] and [7]
This feature determines how the Magellan console will react to a 
Supervision Loss trouble. Table 5 shows the different 
supervision loss combinations available and how the system will 
react when armed or disarmed.
Table 5: Wireless Transmitter Supervision Options
Supervision Bypass Options
Section [094]: Option [8]
Option [8] OFF =No Supervision Loss if detected on a Bypassed 
Zone (default)
Option [8] ON =Generate Supervision Loss if detected on a 
Bypassed Zone
When option [8] is OFF, the Wireless Transmitter 
Supervision Options (page 22) will follow the zone's bypass 
definition. This means the console will not perform any 
action if a Supervision Loss occurs on a bypassed zone.
When option [8] is ON, the Wireless Transmitter Supervision 
Options (page 22) will ignore the bypass definition. This 
means the console will generate an incident as per the set 
Wireless Transmitter Supervision Option if a supervision 
loss occurs on a bypassed zone.
Tamper Recognition Options
Section [094]: Options [3] and [4]
This feature determines how the Magellan console will react to a 
zone tamper. Table 6 shows the different tamper recognition 
combinations available and how the system will react when 
armed or disarmed.
Table 6: Tamper Recognition Options
Tamper Bypass Options
Section [094]: Option [5]
Option [5] OFF =Ignore any tampers detected on a bypassed 
zone (default)
Option [5] ON = Generate tamper if detected on a bypassed 
zone
When option [5] is ON, the Tamper Recognition feature 
(page 22) will ignore the zone’s bypass definition. This 
means the console will generate an incident as per the set 
Tamper Recognition option if a tamper occurs on a 
bypassed zone.
When option [5] is OFF, the Tamper Recognition feature 
(page 22) will follow the zone's bypass definition. This 
means the console will ignore any tampers that occur on a 
bypassed zone.
Check-in Supervision Options
Section [103]: Options [1] to [8]; Zones 1 to 8; Default: All ON
Section [104]: Options [1] to [8]; Zones 9 to 16; Default: All ON
If enabled, Magellan can wait for each of its assigned wireless 
transmitters to send a status signal within a specified time (see 
Check-in Supervision Time on page 23) to confirm their 
Options
Description
[6]
[7]
OFF
OFF
Wireless transmitter supervision disabled
OFF
ON
Trouble only (default)
System armed or disarmed: If a supervision loss 
occurs on a zone, the console will display a trouble on 
the LCD screen and send a report to the central 
monitoring station.
ON
OFF
Audible alarm when armed
System armed: If a supervision loss occurs on a zone, 
the console will follow the zone's Alarm Types setting 
(see page 15).
System disarmed: If a supervision loss occurs on a 
zone, the console will display a trouble on the LCD 
screen.
ON
ON
Audible alarm
System armed: If a supervision loss occurs on a zone, 
the console will follow the zone's Alarm Types setting 
(see page 15).
System disarmed: It functions the same as Trouble 
Only setting, except it will also generate an audible 
alarm.
Options
Description
[3]
[4]
OFF
OFF
Tamper recognition disabled (default)
OFF
ON
Trouble only
System armed or disarmed: If a tamper wiring failure 
occurs on a zone, the console will follow the zone's 
Alarm Types setting (see page 15) and send a report 
to the central monitoring station.
ON
OFF
Audible alarm when armed
System armed: If a tamper failure occurs on a zone, 
the console will follow the zone's Alarm Types setting 
(see page 15).
System disarmed: If a tamper failure occurs on a 
zone, the console will follow the zone's Alarm Types 
setting (see page 15) and send a report to the central 
monitoring station.
ON
ON
Audible alarm
System armed: If a tamper failure occurs on a zone, 
the console will follow the zone's Alarm Types setting 
(see page 15).
System disarmed: It functions the same as Trouble 
Only setting, except it will also generate an audible 
alarm.