Raritan Computer Home Security System 用户手册

下载
页码 384
 
Chapter 14: System Maintenance 
 
 
201
 
3.  Broadcast message: Type the message that will display to users who 
will be logged off CC-SG.  
4.  Restart after (min): Enter the number of minutes (from 0-720) that 
should elapse before CC-SG restarts. 
If specifying over 10 minutes, the broadcast message displays to 
users immediately, and then repeats at 10 and 5 minutes before the 
event occurs. 
5.  Click OK to restart CC-SG. 
 
Upgrading CC-SG 
You can upgrade CC-SG's firmware when a newer version is released. 
You can find firmware files in the Support section of the Raritan website. 
To upgrade CC-SG from version 3.x to version 4.1, you must upgrade it 
to 4.0 first. 
CC-SG version 4.0 or later is not compatible with G1 hardware. Do not 
upgrade a CC-SG G1 unit to version 4.0 or later. 
Download the firmware file to your client PC before proceeding with the 
upgrade. 
Only users with the CC Setup and Control privilege can upgrade CC-SG. 
You should back up CC-SG before upgrading, and send the backup files 
to PCs for safe keeping. See 
Backing Up CC-SG
 (on page 194) and 
Save a Backup File
 (on page 196). 
If you are operating a CC-SG cluster, you must remove the cluster 
before upgrading. Upgrade each CC-SG node separately, then re-create 
the cluster. 
Important: If you need to upgrade both CC-SG and a device or 
group of devices, perform the CC-SG upgrade first then perform the 
device upgrade. 
CC-SG will reboot as part of the upgrade process. DO NOT stop the 
process, reboot the unit manually, power off, or power cycle the 
unit during the upgrade  
 
To upgrade CC-SG: 
1.  Download the firmware file to your client PC. 
2.  Log into the CC-SG Admin Client using an account that has the CC 
Setup and Control privilege. 
3.  Enter Maintenance Mode. See 
Entering Maintenance Mode
 (on 
page 193).