Avaya 03-300430 用户手册
FIBER-LK (Fiber Link)
Issue 1 June 2005
1255
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
Always investigate tests in the following order when inspecting errors in the system. For
example, by clearing error codes associated with the EI Out-of-Frame Query test (#238), you
may also clear errors generated by other tests later in the sequence.
example, by clearing error codes associated with the EI Out-of-Frame Query test (#238), you
may also clear errors generated by other tests later in the sequence.
Table 433: Tests Run for an EI-to-EI Fiber Link
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Sequence
Reset Fiber
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
EI Out-of-Frame Query test (#238)
X
X
ND
EI Neighbor Query test (#237)
X
X
ND
Fiber Link Reset test (#768)
X
D
Table 434: Tests Run for an EI-to-SNI Fiber Link
Order of Investigation
Short Test
Sequence
Sequence
Long Test
Sequence
Sequence
Reset Fiber
Sequence
Sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
EI Out-of-Frame Query test (#238)
X
X
ND
EI Neighbor Query test (#237)
X
X
ND
Configuration audit (#759)
X
X
ND
Failure audit (#777)
X
X
ND
Fiber Out of Frame query (#989)
X
X
ND
Destructive Facility test (#757)
X
D
Off-Board Destructive Facility test (#756)
X
D
Fiber Link Reset test (#768)
X
D