SYNC (Port-Network Synchronization)
Issue 1 June 2005
2167
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its procedures.
This error indicates a problem with the primary DS1 reference. It is cleared when the
primary reference is restored. To find the problem’s source:
primary reference is restored. To find the problem’s source:
1. Enter list configuration board location to check if the primary DS1 Interface
circuit pack is inserted in the carrier.
2. Verify that the administered primary reference matches the DS1 reference from the
network synchronization plan.
3. Enter test board location long to test the primary DS1 Interface circuit pack.
Check the Error Log for DS1-BD or UDS1-BD errors and see
resolve errors associated with the primary DS1 (DS1 or UDS1) interface circuit pack.
If the only errors against DS1-BD or UDS1-BD are slip errors, follow the procedures
described in the previous troubleshooting section. If no errors are listed in the Error Log
for the primary DS1 Interface circuit pack, continue with the following steps.
described in the previous troubleshooting section. If no errors are listed in the Error Log
for the primary DS1 Interface circuit pack, continue with the following steps.
None
WRN
MIN (
OFF
None
18 (
0
disable sync
WRN
OFF
enable sync
257 (
)(
)
None
WRN
MIN (
OFF
None
513 (
)(
)
None
WRN
MAJ (
OFF
None
769 (
)
None
MAJ
OFF
None
1793 (
)
1
0–50
None
MAJ
OFF
None
2049 (
)
0
None
WRN
OFF
None
1. It can take up to 1 hour for these alarms to clear.
Table 771: Synchronization Maintenance Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value