Communication Manager Maintenance-Object Repair Procedures
2508 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1002
ABRT
No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
G700
:
1412
ABRT
On the G700, this test aborts with Error Code 1412.
1963
ABRT
The port is in use.
1. Retry the command when the port is idle. You can force the port to the
idle state with busyout port location.
Note: This command is destructive, tearing down every call and link
using the port.
Note: This command is destructive, tearing down every call and link
using the port.
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
●
If this problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
location, reset board location, and release board
location).
●
If the problem persists, replace the circuit pack.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
2100
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
FAIL
VAL circuit pack detected test failure.
●
If the problem persists, reset the circuit pack (busyout board
location, reset board location, and release board
location).
location, reset board location, and release board
location).
●
If the problem persists, replace the circuit pack.
PASS
Port circuitry functioning properly.
Table 889: Test #1275 SCOTCH Synchronous Loop-Around Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2