K0022V3  3/09  Rev. A 
ADEMCO 6150V & 6160V
Voice Remote Keypads
INSTALLATION AND SETUP GUIDE 
GENERAL INFORMATION 
The ADEMCO 6150V and ADEMCO 6160V are addressable 
remote keypads designed for use with ADEMCO control 
panels and provide the following features:   
•  Backlit Display 
• Voice Chime 
•  Programmable Function Keys 
•  Built-in Sounder 
• Voice Status 
• Message Center 
•  Supervised by control panel (if supported) 
Notes:   
•  When used with the ADEMCO VISTA-15P/VISTA-
20P control panels, address 16 must be assigned to 
the first keypad.  Additional keypads must be 
assigned to address 17 – 23.  Refer to Setting The 
Keypad Options.  
 
•  Keypad keys are continuously backlit for convenience.   
•  Permanent display backlighting is an option on some 
controls (refer to control panel’s instructions for details).  
•  Voice Chime should only be enabled when used with 
control panels that support the "chime by zone" mode 
(e.g., VISTA-15P/VISTA-20P).  This mode must be 
enabled at the control panel.  Refer to the control panel's 
installation and setup guide for information on how to 
program the chime mode.   
•  Use only zone descriptors supported by this 
keypad.  If using zone descriptors not supported 
by this keypad, you must turn voice status and 
voice chime off.  Table 1 is a list of applicable zone 
descriptors and index entries.  
Refer to  the control 
panel’s installation and setup guide for information 
about how to program zone descriptors.   
•  For the 6160V ONLY, supervision must be enabled for 
commercial fire installations. 
UL NOTE: ADEMCO 6150V cannot be used for commercial 
fire applications. 
KEYPAD DISPLAYS AND LEDS 
The keypads have the following display features: 
Model
 
Fixed 
Word 
Display
 
2-Line 
Alpha 
Display
 
2-Digit 
Zone 
Identifier
 
Custom 
Zone 
Descriptors
6150V
 
X   X   
6160V
 
 X    X 
The following table identifies the keypad’s LEDs and 
associated functions: 
LED
 
Function
 
ARMED
 
Lights red when the system is armed in any mode.
 
READY
 
Lights green when the system is "ready" to be 
armed.
 
MESSAGE
 
Flashes red when message waiting or lights red 
(steady) when in record mode.
 
PROGRAMMABLE FUNCTION KEYS 
The keypad's programmable function keys [A, B, C] are 
normally used for keypad panic functions, but they can be 
programmed for other special functions instead.  If they are 
programmed for other special functions, the associated 
keypad key pairs still provide the respective panic alarm (if 
programmed).  Refer to the control panel’s Installation & 
Setup Guide for details.  
Function 
Keys 
Equivalent Key Pairs 
A
 
[1] and [*]
 
B
 
[*] and [#]
 
C
 
[3] and [#]
 
D
 
NONE 
 
 
• 
Function  keys  must  be  held  down  for  at 
least 2 seconds to activate the programmed 
function. 
 
• 
If functions other than panics are assigned 
to the programmable function keys, 
programmed panics must be initiated by 
pressing the programmed key pair.
 
FUNCTION KEY LABELS
 
A set of adhesive-backed labels with some typical function 
symbols (i.e., fire, police, personal emergency, etc.) is 
provided.  These labels can be placed on or next to the keys 
to identify each key's function for the end user (as 
determined by the capability and programming of the 
control panel; refer to the installation and setup guide for 
the control panel). 
6160V
-001-V1
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
the keypad's bottom edge and pulling the case apart.)
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
MESSAGE
MIC
ARMED
READY
RECORD
VOLUME
PLAY
STATUS
FUNCTION
VOICE
SIDE
VIEW
D
C
B
A
 
WIRING AND INSTALLATION 
Keypads can be surface mounted using drywall anchors or 
to a single- or double-gang electrical box.  
1.  Remove the case back by pushing up the two "snaps" 
along the keypad’s bottom edge and pulling the case 
apart.  See diagram above. 
2.  Route wiring from the control panel through the 
opening in the case back. 
3.  Mount the case back to a wall or electrical box.  
4.  Wire directly from the keypad’s terminal block to 
the terminal block on the control board. (See Wiring 
Table that follows.)  Use only 16-24 AWG wire. 
Wiring Table (All Keypads) 
Keypad 
Control Panel 
Wire Color 
G 
Data In 
Green 
 
– Aux Pwr (GND) 
Black 
+ 
+ Aux. Pwr 
Red 
Y 
Data Out 
Yellow 
5.  Re-attach the keypad to the case back. 
6.  Remove clear protective film from LEDs (6160V 