Honeywell 6160V 产品宣传页

下载
页码 2
 
ÊK0022V36Š 
K0022V3  3/09  Rev. A 
SETTING THE KEYPAD OPTIONS 
The procedures that follow are used to set the keypad 
address, voice chime mode, and additional voice keypad 
mode.   
Setting The Keypad Address  
 
When used with the VISTA-15P/VISTA-20P 
control panels, address 16 must be assigned to 
the first Keypad.  Additional Keypads must be 
set at 17 - 23 and must be enabled additionally 
in control programming (fields *190 - *196).  
 
The keypad can either be set for an address of 00-30 or for 
non-addressable mode (31).  The default keypad address is 
31.  For valid address settings for your keypad, refer to the 
control panel's Installation & Setup Guide.   
Note:   
•  If unable to enter the address mode, power down, 
power up, and try again. 
•  If 10 seconds pass with no key entry, the keypad 
automatically exits the address mode.  You must 
power down, power up, and start the address mode 
again.   
•  The keypad will not enter the address mode if the 
control panel is in programming mode.   
1.  Apply power to the keypad.   
2.  Within 60 seconds of applying power to the keypad, press 
and hold down the [1] key and [3] key at the same time 
for 3 seconds.  The current keypad address will be 
displayed.   
3.  Press "00".   
The current address is cleared.   
4.  Enter desired keypad address.   
5.  Press [*] to save the displayed address and enter the 
Voice Chime mode.  "VOICE CHIME" (alpha keypad) or 
"C" (fixed keypad) is displayed along with the selected 
mode "1" or "0".   
Setting The Voice Chime Mode 
6.  Press [1] to set the Voice Chime mode on or press [0] to 
set the Voice Chime mode off.   
7.  Press [*] to save the displayed Voice Chime mode and 
enter the Additional Console voice keypad mode.   
"ADDITIONAL CON" (alpha keypad) or "A" (fixed 
keypad) is displayed along with the selected mode "1" or 
"0".   
Note:  Setting Voice Chime mode off does not effect the 
voice status or alarm annunciation.   
Setting The Additional Console Mode   
The Additional Console mode must be set for all voice 
keypads being used.   
8.  Set the voice keypad Additional Console mode as 
follows:   
a.  On the Primary voice keypad, press [0] to set the 
Additional Console mode to NO. 
b.  On any secondary voice keypads, press [1] to set 
Additional Console mode to YES. 
9.  Press [*] to save the mode.   
VIEWING THE KEYPAD ADDRESS 
Press and hold down the [1] key and [3] key at the same 
time for about 3 seconds.  The current address is displayed.  
No key entry is allowed.  Press any key to exit or wait 10 
seconds to exit the viewing mode.   
OPERATING THE KEYPAD 
For operating instructions, see the User Guide for the 
control panel used with this keypad. 
SPECIFICATIONS 
Physical: 
6150V: 
4-7/8"H x 6-1/4"W x 1"D 
6160V: 
5-5/16"H x 7-3/8"W x 1-3/16"D 
Displays: 
6150V: 
Fixed-Word LCD (backlit) 
6160V: 
2 x 16 Alpha-Numeric Super twist LCD 
(backlit) 
Sounder: 
Speaker 
Electrical: 
Voltage:  
+12VDC 
(power-limited) 
Current: 
6150V: 
160mA (ARMED LED lit, LCD backlight and 
sounder on) reduces to 60mA when panel is 
operating in standby mode (backlight off). 
6160V:  
190mA (ARMED LED lit, LCD backlight and 
sounder on) reduces to 60mA when panel is 
operating in standby mode (backlight off). 
NFPA72 Compliant. 
 
TABLE 1.  ZONE DESCRIPTORS AND INDEX ENTRIES 
ALARM 002 
DOOR 
057 
KITCHEN 
105 PATIO 
146 UPSTAIRS  
207 
ATTIC 009 
EMERGENCY 
067 
LAUNDRY 
106 
POLICE 
151 
UTILITY  
208 
BABY 012 
EXIT 
071 
LIBRARY 
109 
POOL 
152 
WINDOW  
217 
BACK 013 
FIRE 
079 
LIVING 
113 
ROOM 
162 
YARD  
223 
BASEMENT 016 
FLOOR 
080 
MAIN 
122 
SHED  
168 
ZONE  
225 
BATHROOM 017 
FRONT 
085 
MASTER 
123 
SHOP  
170 
1ST  
228 
BEDROOM 019 
GARAGE 
089 
MEDICAL 
125 
SIDE  
173 
2ND  
230 
CLOSED 
040 
GUN 
094 
MOTION 
131 
SLIDING  
175 
3RD  
232 
DEN 
050 
HALL 
095 OFFICE 
136 SMOKE  
176 
 
 
DETECTOR 
052 
HOUSE 
099 OPEN 
138 STORAGE  
185 
 
 
DINING 
053 
INSIDE 
101 PANIC 
144 SUPERVISED  
190 
 
 
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR 
WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 
 
For the latest warranty information, please go to:                    
http://www.security.honeywell.com/hsc/resources/wa/index.html
 
 
 
2 Corporate Center Drive, Suite 100, P.O. Box 9040, Melville, NY  11747 