Introduction
Vented wall furnace is shipped ready to install in a 2" x 4"  stud 
wall, with studs 16" (406mm) center to center.  Always consult 
your local Building Department regarding regulations, codes 
or ordinances which apply to the installation of a  vented wall 
furnace.
Instructions to Installer
1.  Installer must leave instruction manual with owner after 
installation.
2.  Installer must have owner Þ ll out and mail warranty card 
supplied with furnace.
3.  Installer should show owner how to start and operate furnace 
and thermostat.
Warning:
Any change to this furnace or its control can be dangerous.  
This is a heating appliance and any panel, door or guard 
removed for servicing an appliance must be replaced prior 
to operating the appliance.
General Information
This series is design certiÞ ed in accordance with American National 
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian 
Standards Association, as a Vented Wall Furnace and must be 
installed according to these instructions.
Any alteration of the original design, installed other than 
as shown in these instructions or use with a type of gas not 
shown on the rating plate is the responsibility of the person 
and company making the change.
Important
All correspondence should refer to complete Model No., Serial 
No. and type of gas.
Notice:  During initial Þ ring of this furnace, its paint will bake 
out and smoke will occur.  To prevent triggering of smoke alarms, 
ventilate the room in which the furnace is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed 
so that all burners and burner ignition devices are located not less 
than 18" (457mm) above the ß oor.
Such equipment shall be located, or protected, so it is not subject 
to physical damage by a moving vehicle.  
QualiÞ ed Installing Agency
Installation and replacement of gas piping, gas utilization equipment 
or accessories and repair and servicing of equipment shall be 
performed only by a  qualiÞ ed agency.  The term "qualiÞ ed 
agency" means any individual, Þ rm, corporation or company 
which either in person or through a representative is engaged in 
and is responsible for (a) the installation or replacement of gas 
piping or (b) the connection, installation, repair or servicing of 
equipment, who is experienced in such work, familiar with all 
precautions required and has complied with all the requirements 
of the authority having jurisdiction.
State of Massachusetts: The installation must be made by 
a licensed plumber or gas Þ tter in the Commonwealth of 
Massachusetts.
The installation must conform to local codes  or, in  the absence of 
local codes, with the National Fuel Gas Code ANSI  Z223.1/NFPA 
54* Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11 West 42nd 
St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input ratings 
should be reduced at the rate of 4 percent for each 1,000 (305m) 
feet above sea level. Canadian High Altitudes for locations having 
an elevation above mean sea level between 2,000 feet (610m) and 
4,500 feet (1370m), the manifold pressure is to be decreased from 
3.5" w.c. (.871kPa) to 3.0" w.c. (.747kPa) for Natural Gas and from 
10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa) for Propane Gas.
INTRODUCTION
Model  
GWT-50
Input BTU/HR (KW/H) 
50,000 (14.7)
Height  
66 1/8" (168cm) 
Width 16" 
(406mm)
Depth (Out of wall) 
6" (152mm)
Gas Inlet Pipe 
1/2" 
Vent Pipe Type B Oval 
4" (102mm) 
Accessory
Blower Package  
GWTB-2
GWT-50 (SG, RB) is a DUAL WALL Furnace.  Warmed air is discharged into two rooms which share a common wall. 
SPECIFICATIONS