Empire Comfort Systems GWT-50-2 用户手册

下载
页码 20
12426-4-0104 
    Page 7
Check all local codes for requirements, especially for the size and 
type of gas supply line required.
Recommended Gas Pipe Diameter
  Pipe Length 
Schedule 40 Pipe 
Tubing, Type L
 
(Feet) 
Inside Diameter 
Outside Diameter
 
 
Nat. L.P.  Nat.  L.P.
 0-10 
1/2"  3/8" 
1/2"  3/8"
 
 
1.3 cm 
1.0 cm 
1.3 cm 
1.0 cm
 10-40 
1/2"  1/2" 
5/8" 
1/2"
 
 
1.3 cm 
1.3 cm 
1.6 cm 
1.3 cm
 40-100 
1/2" 
1/2" 
3/4" 
1/2"
 
 
1.3 cm 
1.3 cm 
1.9 cm 
1.3 cm
 100-150 
3/4" 
1/2" 
7/8" 
3/4"
 
 
1.9 cm 
1.3 cm 
2.2 cm 
1.9 cm
Note: Never use plastic pipe. Check to conÞ rm whether your local 
codes allow copper tubing or galvanized.
Note: Since some municipalities have additional local codes, it is 
always best to consult your local authority and installation code.
Check all local codes for requirements, especially for the size and 
type of gas supply line required.  On Natural gas lines less than 15' 
(4.57m) long, use 1/2" pipe; on longer runs,  use 3/4" iron pipe or 
equal.  On  LP gas lines please consult LP gas supplier.
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
In the state of Massachusetts the gas cock must be a T handle 
type.
A manual main gas cock should be located in the vicinity of the unit. 
Where none exists, or where its size or location is not adequate, con-
tact your local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant 
to the action of liqueÞ ed petroleum gases. The gas lines must be 
checked for leaks by the installer. This should be done with a soap 
solution watching for bubbles on all exposed connections, and if 
unexposed, a pressure test should be made. 
Never use an exposed ß ame to check for leaks. Appliance must 
be disconnected from piping at inlet of control valve  and pipe 
capped or plugged for pressure test. Never pressure test with 
appliance connected; control valve will sustain damage!
A gas valve and ground joint union should be installed in the gas 
line upstream of the gas control to aid in servicing. It is required by 
the National Fuel Gas Code that a drip line be installed near the gas 
inlet. This should consist of a vertical length of pipe tee connected 
into the gas line that is capped on the bottom in which condensation 
and foreign particles may collect. 
GAS SUPPLY
Figure 1
The use of the following gas connectors is recommended:
—  ANS Z21.24 Appliance Connectors of Corrugated Metal 
Tubing and Fittings
—  ANS Z21.45 Assembled Flexible Appliance Connectors of 
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority 
having jurisdiction. The state of Massachusetts requires that a 
ß exible appliance connector cannot exceed three feet in length.
Pressure Testing of the Gas Supply System
1.  To check the inlet pressure to the gas valve, a 1/8" (3.175mm) 
N.P.T. plugged tapping, accessible for test gauge connection,  
must be placed immediately upstream of the gas supply 
connection to the appliance.
2.  The appliance and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
1/2 psig (3.5 kPa).
3.  The appliance must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psig (3.5 kPa).
Attention!  If one of the procedures results in pressures in excess 
of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will 
result in a hazardous condition.
Checking Manifold Pressure
Both Propane and Natural gas valves have a built-in pressure 
regulator in the gas valve.  Natural gas models will have a manifold 
pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet 
with the inlet pressure to the valve from a minimum of 4.5" w.c. 
(1.120kPa) for the purpose of input adjustment to a maximum of 
10.5" w.c. (2.614kPa)   Propane gas models will have a manifold 
pressure approximately 10.0"  w.c. (2.49kPa) at the valve outlet 
with the inlet pressure to the valve from a minimum of 11.0" w.c. 
(2.739kPa) for the purpose of input adjustment to a maximum of 
13.0" w.c. (3.237kPa).  
A 1/8" (3.175mm) N.P.T. plugged tapping, accessible for test gauge 
connection, is located on the outlet side of the gas control.