624WBPF Woodburning Fireplace
chiMNey iNStallatioN
1.  Lay  out,  cut  and  frame  openings  through  all  ceilings  and  the  roof  at  the  point  where  the  chimney  will  pass 
through. Unless the chimney is to be offset, the point where the center line of the chimney will pass through the 
ceiling and roof can be determined with a plumb line as shown in Figure 10. The fireplace should be located in 
the planned installation position. After the center line is established and a nail is driven to mark the point, the 
opening can be cut if you are satisfied with the chimney location relative to ceiling and roof joists and/or any other 
obstructions. The roof  opening center line should be marked by driving a nail through the roof from underneath 
that will penetrate the roof and can be located from the rooftop. If the chimney is to penetrate a pitched roof, the 
hole in the roof must be rectangular instead of square and should be sized according to Table1.
2.  Install the firestop spacer as required from beneath the ceiling unless the space above is attic space. In an attic, 
the firestop spacer should be installed at the floor level of the attic. You must have joists or headers on all four 
sides of the spacer and use a minimum of four 8-penney nails to secure the spacer.
3.  To install the chimney sections, insert the male end of the flue, the smallest diameter pipe, into the flue outlet of 
the fireplace and press down until the snap locks engage. Continue the process, adding the chimney sections 
on top of each other until the chimney is at least six inches above the roof opening on all sided. As the chimney 
sections are installed, check each joint to make sure it is properly locked to the previous section. If additional 
strength of the outer pipe joints is desired, you may use two or three sheet metal screws placed through the area 
where the outer pipes overlap one another. To install these screws, drill a 1/8-inch diameter hole through the 
chimney sections, taking care not to penetrate the inner flue pipe.  WarNiNg:  Be very careful when drilling the 
holes into the outer pipe. The drill must not penetrate the inner stainless steel pipe.
Note:  If you intend to have a total fireplace installation of more that 30 feet you must use chimney support model 
11CS at or below 30 feet to support the weight of additional chimney pipe.
To install the chimney support, place the crimped end of the flue and outlet air duct portions into the last section 
of chimney pipe. Push down until the outside or inlet air duct of the chimney support overlaps and snap locks the 
chimney support into the chimney section.
Nail the support straps tightly to a building frame member or ceiling joist as shown by Figure 14. You must use at 
least two 8-penney nails per strap.
elbow installation
The following are important points that should be observed 
when installing elbows on the fireplace:
1.  The support straps of all elbows not installed directly on 
top of the fireplace should be nailed securely to the sur-
rounding structure. This allows the support strap to carry 
the weight of the chimney above the elbow and prevents 
this weight from breaking the elbow or chimney sections 
apart.
2.  Elbows  should  not  be  used  in  any  combination  that  in-
clines the chimney more than 30 degrees from vertical.
3.  The limitations on the quantity of elbows per chimney are 
as follows: If the total height of the fireplace and chimney 
is—13’  or  more  —  two  (2)  elbows  may  be  used  in  the 
chimney.  21’ or more — four (4) elbows may be used in 
the chimney.
4.  The inclined portions of chimneys that pass through liv-
ing spaces likely to be used for storage should be enclosed to avoid contact with and possible damage to the 
chimney. The minimum air space of 2” between the chimney and enclosing materials must be maintained.
5.  The length of the inclined portion of chimney between elbows must not exceed 6’ when unsupported or 20’ if the 
chimney is supported at 6’ intervals with support such as metal support straps.
6.  When enclosing the elbows and inclined portions of the chimney, enclosing materials must be installed vertically 
to maintain the required 2” minimum air space clearance to the chimney at the extremities of the offset.  It is 
recommended that enclosing material not follow the inclined portions of the chimney.
FP1893
30 elbow 
8/08
Figure 14
Inlet Air 
Pipe
Flue
All four (4) support straps must be nailed on to framing member 
around the elbow with a minimum of two (2) 8-Penny nails per 
strap
Note:  Although  both  halves  of  the  elbow  set  may  have  tie 
straps, only the top half must be secured. The bottom elbow half 
is not required to be secured for added stabilization of pipe.
FP1893