624WBPF Woodburning Fireplace
chimney requirements - offset installations
 
0   0   0   0   0  
3"  
11"
  1   0   0   0   0  
8Z\₄"  
20"
  0   1   0   0   0   11Z\₄"   25Z\₄"
  2   0   0   0   0   13Z\x"   29Z\₄"
  1   1   0   0   0   16Z\x"   34Z\₄"
  0   0   1   0   0   20Z\₄"   40³\₄"
  2   1   0   0   0   21³\₄"   43Z\x"
  0   0   0   1   0   26Z\₄"   51Z\₄"
  0   1   1   0   0   28Z\x"   55Z\₄"
  1   0   0   1   0   31Z\x"   60Z\₄”
  0   1   0   1   0   34Z\x"   65Z\x"
  0   0   2   0   0   37Z\x"   70³\₄"
  1   1   0   1   1   41Z\x"   77³\₄"
  0   0   1   1   1  
45"   83³\₄"
  0   1   2   0   1   47Z\₄"   87Z\x"
  0   0   0   2   1  
51"  
94"
  0   1   1   1   1   53Z\₄"  
98"
  0   0   3   0   1   56Z\₄"   103Z\₄"
  0   1   0   2   1   59Z\₄"   108Z\x"
  0   0   2   1   1   62Z\₄"   113Z\x"
  0   1   3   0   1   64Z\x"   117Z\x"
  0   0   1   2   1   68Z\₄"  
124"
  0   1   2   1   1   70Z\x"  
128"
  0   0   0   3   1   74Z\₄"   134Z\x"
  0   1   1   2   2  
78"   140³\₄"
  0   0   3   1   2  
81"  
146"
  0   1   0   3   2  
84"   151Z\₄"
  0   0   2   2   2  
87"   156Z\x"
  0   1   3   1   2   89Z\₄"   160Z\₄"
  0   0   1   3   2  
93"   166³\₄"
  0   1   2   2   2   95Z\₄"   170³\₄"
  0   0   0   4   2   99Z\₄"   177³\₄"
  0   1   1   3   2   101Z\₄"   181³\₄"
  0   0   3   2   2   104Z\₄"   186Z\₄"
  0   1   0   4   2   107Z\₄"   191Z\x"
  0   0   2   3   2   110Z\₄"   196³\₄"
  0   1   3   2   3  
114"   203Z\₄"
  0   0   1   4   3   117³\₄"   209³\₄"
  0   1   2   3   3  
120"   213Z\x"
  0   0   0   5   3   123³\₄"  
220" 
30° elbow offsets
1' 1¹⁄₂' 3' 4'
c
himney
Support
offset
rise
Notes:   G + H cannot exceed 20 feet. 
*11CF Chimney airspace clearance = 2" minimum.
illustration key
The following safety rules apply to offset 
installations (letters correspond with illustra-
tion above): 
a. Height of the chimney is measured from 
the hearth to the chimney exit.
 
   
624WBPF
Max.:  
86’0”
Min.:
0 Elbows 
14’0"
2 Elbows* 
14’0”
4 Elbows* 
21'0"
B. Do not use more than 4 elbows per chim-
ney.
Attach the straps of the return (top) elbow to a 
structural framing member.
The offset (first) elbow of any pair does not 
have straps.
FP269
c. The chimney cannot be more than 
30° from the vertical plane in any instal-
lation.
d. The maximum length of the angled 
run of the total chimney system is 20 
feet. (G plus H cannot exceed 20 feet.)
e. A chimney support (Model 11CS) 
is required every 6 feet of angled run 
of chimney. Chimney supports are 
required for every 30 feet and 60 feet 
chimney height above the hearth. 
Determine the offset distance of your 
chimney arrangement from the center-
line of the fireplace to the centerline of 
the chimney where it is to pass through 
the first ceiling. 
Note: This offset distance may not be 
your full offset distance. See Examples 
2 and 3.
IWF282
MBUF
5/26/96
Offset
Rise
FP282
D
B
G
H
B
C
E
6 FT.
G
H
A
IWF269
MBUF
5/16/96
rev. 5/25
30° 
Return
Elbow
Chimney Flue Exit
Chimney 
Section
rise
30° 
Offset 
Elbow
11CS Sup-
port
offset
30° 
Offset 
Elbow
30° 
Return 
Elbow
example 1
example 2
example 3
Elbow
Hearth Floor
Figure 17
chiMNey oFFSet iNStallatioN