New Buck Corporation DV23ZC 用户手册

下载
页码 33
INSTALLATION 
 
HIGH ALTITUDE 
 
This unit is approved in Canada for altitude from 0 to 2,000 ft. (0 to 600m) (Can 2.17-M90) with the main 
burner orifice supplied.  For installations above 2,000 feet, follow current CAN/CGA-B149.1 and B149.2.  
In the USA refer to ANSI Z223.1 — latest edition, Appendix F, for resizing the orifice. 
 
At altitudes greater than 2,000 feet it is necessary to match the air and fuel requirements by installing a 
main burner orifice sized for the elevation that the appliance is installed at by referencing the chart shown 
below.  Be sure to check both front and rear orifice for proper drill size. 
 
DRILL SIZING CHART 
RECOMMENDED SIZE vs. ALTITUDE 
 
ALTITUDE    NATURAL 
GAS 
  PROPANE 
(LPG) 
                                                        Front                     Rear              Front                  Rear 
  2,000 ft /   600m   
 
     # 50                       # 59                #1.25mm            # 68
 
 
 
 
  3,000 ft /   900m                           #  51                       # 61                #  56                    # 69 
 
  4,000 ft / 1200m                           # 51                        # 61                # 57                    # 69 
 
  5,000 ft / 1500m                           # 51                        # 62                # 57                    # 69 
 
  6,000 ft / 1800m                           # 52                        # 62                # 57                    # 70 
 
  7,000 ft / 2100m                           # 52                        # 63                # 58                    # 70 
 
  8,000 ft / 2400m                           # 52                        # 64                # 59                    # 70 
 
  9,000 ft / 2700m                           # 53                        # 64                # 59                    # 71 
 
10,000 ft / 3000m                           # 53                        # 65                # 60                    # 71 
 
 
 
The above orifice sizing chart should be used as a guide only.  Actual orifice size may be 
different due to venting configuration and actual altitude.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
17