Enviro EG 28 B 用户手册

下载
页码 20
 
 
14
PARTS AND ACCESSORIES 
 
Service Parts available from your local Envirogas Dealer 
 
Burner Control Assembly 
Natural Gas Pilot Assembly 
Propane Pilot Assembly 
Door Bolt 
Relief Door Gasket 
Regulating Valve 
Piezo Igniter 
Burner Switch 
B-vent Spill switch 220
°  
Orifice Blank 
Convection Blower 
Light Bulb Holder 
Light Switch (momentary) 
Fan Controller  
Log Set (with Embers) 
Thermocouple 
Embers 
Thermopile 
Door Gasket 
Convection Fan Sensor 120
° (48°C) 
 
Accessories 
 
Gold trim Package  
Low Voltage Thermostat 
 
 
 
 
 
REMOVING or INSTALLATION OF THE BLOWER 
 
1.  Turn the unit off and remove the log set.  
 
2.  Remove the burner tray assembly by 
removing the screw on either side of the 
tray, between the front and rear burners. 
Lift the tray out
 
 
3.  Remove the 4-5/16” bolts that hold the 
blower mounting plate to the back firewall. 
Use a light lubricating oil on screws before 
removal. 
 
4.  Carefully pull the assembly into the firebox.  
Install the blower onto the mounting 
bracket (blower outlets pointing through the 
two holes in the bracket) using the 4 
screws provided. 
 
5.  Connect wires according to the wiring 
diagram.  (If removing the blower, 
disconnect the blower leads from the 
harness.  Remove the blower.) 
 
6. Check mounting plate gasket and reverse 
steps 1 through 4.