Enviro EG 28 B 用户手册

下载
页码 20
 
ADJUSTING THE VENTURI 
 
•  Remove the ash shelf by undoing the screw at 
each end, pull shelf towards you. 
•  Remove one screw from the cover plate located 
below the ash shelf. Loosen the other screw (do 
not remove) swing the cover plate out of the way 
and tighten screw down to hold it in place. 
•  With along screwdriver rotate spring clips to open 
or close the shutter to the desired setting. 
•  The burner flame should be a bright 
yellow/orange when hot.  Excessive blue is to 
lean and dark orange with soot is too rich. 
 
FUEL CONVERSION 
 
“Warning”  This conversion kit shall be installed 
by a qualified service technician in accordance 
with the manufacturer’s instructions and all applicable codes and requirements of the authority having 
jurisdiction.  If the information in these instructions is not followed exactly, a fire, explosion or CO 
poisoning may result.  The qualified service agency is responsible for the proper installation of this kit.  
The installation is not proper or complete until the operation of the converted appliance is checked as 
specified in the owner’s conversion kit. 
 
Please read and follow these instructions. Also please read the instruction guide lines provided by S.I.T on how to 
remove and install the HI-LOW regulator. 
 
STEP 1.   
Carefully inspect all parts supplied with this conversion kit.  
STEP 2.   
Shut the gas off and disconnect the main gas line from the unit. 
STEP 3.   
Open the door by unscrewing the ½” bolt on the right hand side of the stove.  Lift door off the hinges mounted on 
the left-hand side. Remove the burner tray top for the appliance 
STEP 4.   
Change the regulator on the front of the gas valve. (Follow the instructions provided by S.I.T) 
STEP 5.   
To change the pilot orifice: First, remove the two (2) T-20 Torx screws that hold the pilot assembly to the burner 
tray.  Lift the pilot assembly from the burner tray.  Using a 10mm wrench, disconnect the pilot line from the pilot 
assembly and remove the pilot injector. Install the new pilot injector. 
(BE CAREFUL WHEN TIGHTENING THE PILOT FITTING, YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE).  
STEP 6.   
Re-install the pilot assembly in the reverse order of STEP 5. 
STEP 7.   
Remove the burner orifice with a ½” deep socket. 
STEP 8.   
Install the new orifice supplied making sure that the orifice is in the correct location. Be sure to put a bead of pipe 
thread sealant or approved Teflon tape on the orifice before installing into the burner assembly. 
STEP 9.   
Reinstall the burner tray, log set and door. 
STEP 10. 
Re connect the gas line to the unit.  Do a leak check using a soap and water solution or an approved manner on 
the gas supply line and the pilot tubing.  
STEP 11. 
Re-light the appliance to insure proper operation and proper flame appearance. Be sure to adjust the venturi setting 
to achieve an efficient flame in the fireplace. 
STEP 12. 
MAKE SURE that the sticker provided by S.I.T is installed to signify that this valve has been converted to a different 
type of fuel. Also make sure that the rating plate has a conversion label to show that this unit has been converted to 
a different fuel type. 
 
A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE 
REGULATOR IS THE CORRECT PART.  A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE 
CORNER ON THE KNOB. 
 
1 50% turn down HI-LOW Regulator w 3 T-20 Torx 
screws 
1 T-20 tamper proof Torx screwdriver bit 
1 pilot injector 
1 Main orifice 
1 Pilot assembly mounting gasket 
 NATURAL 
GAS 
PROPANE 
Pilot Orifice. 
.51mm 
.35mm 
Burner Orifice. 
#42 dms 
#53dms 
Venturi Settings 
1/16” min 
¼” min 
 
 