United States Stove 3600PB 用户手册

下载
页码 20
6
It is extremely important that you respect required installation distances and that you respect local 
installation regulations.  This is for your safety!  The manufacturer is not responsible for the product, 
if it is not installed following these recommendations.  These clearances may only be reduced by 
means approved by the regulatory authority.
One necessary precautions when installing a wood stove is to leave sufficient space between the 
stove (top, sides, back, front, and under stove pipes) and any other material that can catch fire.
A combustible surface is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics etc.) 
These surfaces are not limited to those that are visible and also include materials that are behind 
non-combustible materials.  If you are not sure of the combustible nature of a material, consult your 
local fire officials.
Installation Clearances
3600PB
Single Wall Connector Pipe
3800PB
Single Wall Connector Pipe
A – Chimney Connector to backwall
15.5” (394 mm)
21.5” (546 mm)
B – Chimney Connector to sidewall
28” (711 mm)
29” (737 mm)
C – Chimney Connector to cornerwall
15” (381 mm)
21.5” (546 mm)
D – Unit to backwall
13” (330 mm)
17” (432 mm)
E – Unit to sidewall
20” (508 mm)
20” (508 mm)
F – Unit to cornerwall
7” (178 mm)
11.5” (292 mm)