United States Stove 3600PB 用户手册

下载
页码 20
7
Only materials and items approved for solid fuel stoves should be used for your stove.  Under no 
circumstances should you use aluminum or galvanized steel pipes for your stove flue.  
Always fit pipes with the narrow side down, this allow any creosote to run down the inside of the 
pipe and not to come out and cause an unsightly mess and possible fire hazard. All joints in the flue 
system should be sealed with fire cement and/or an appropriate fire resistant rope or gasket.  
Pipe bends should be kept to a minimum and we do not recommend using more than 2 bends on 
any installation. Flues must not pass through ceilings, floors, attics, roofs, or combustible walls with-
out adequate and approved insulation being provided to protect combustible materials. 
The chimney and flue provide a means of taking combusted fuel from the stove, as well as a draft to 
enable the stove to work. It is essential that the flue system is kept in good condition and there are 
no breaks or cracks allowing contact with any other combustible materials of the house. It is also 
essential that the flue system is kept clean and seals are maintained to ensure the draft is not lost.
The open end of the flue system must be above the height of the apex of the building and any other 
obstructions, such as trees, which are within 3 meters (10ft) of the flue system. Failure to do this will 
affect the efficiency of the stove and may cause down drafts which will mean dangerous products of 
combustion are emitted into room. 
Under no circumstances should the flue pipe be less than 6” (125mm) internal diameter. 
Installation Clearances
The chimney connector is a single walled pipe used to connect the stove to the chimney. For use 
with the appliance the chimney connector MUST be 6” in diameter, with a minimum thickness of 24 
gauge black steel or 26 gauge blued steel.
Aluminum and galvanized steel pipe is not acceptable for use with the appliance. These materials 
cannot withstand the extreme temperatures of a wood fire and can give off toxic fumes when heated. 
Do not use the connector pipe as a chimney�
Each chimney connector or stovepipe section must be installed to the stove flue collar and to each 
other with the male (crimped) end toward the stove. See fig 5.
Chimney Connection