Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENTING
:
 
This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” 
PIPE  FOR  GAS  STOVES,  SECURITY  CHIMNEY’S  SECURE  VENT  DIRECT  VENT  SYSTEM  kits,  and  MDV 
SELKIRK METALBESTOS.
2" (51mm)
5" (127mm)
12
5
/
16
"
(313mm)
45
15
/
16
"
(1167mm)
Figure 19. Vent Framing Through Wall/Ceiling
Figure 18. Vent Pipe Clearances.
A 1” (25 mm) clearance to combustibles must be maintained 
around  any  vertical  vent  pipe.  Around  a  horizontal  vent 
pipe,  the  clearance  to  combustibles  should  be  2”  (51  mm) 
above  and  11⁄2”  (38  mm)  on  the  sides  and  bottom.  When 
combustible materials are directly above a 90° elbow, 5” (127 
mm) of clearance are necessary. See Figure 18
A 10” (254 mm) x 10” (254 mm) frame (see Figure 19) will 
assure the proper support and spacing for the vent pipe as it 
passes through the wall. Installations in Canada require that 
a wall thimble be used for passing through walls and ceilings. 
All sealing and vapour barriers must comply with local building 
codes.
When  planning  an  installation,  it  is  necessary  to  select  the 
proper length of vent pipe for the particular requirements.   The 
configuration of the venting pipes depends on the locations 
of  walls,  ceilings  and  studs.  However,  the  pipes  cannot  be 
of arbitrary length and arrangement. Because the length of 
the  vertical  and  horizontal  sections  dramatically  affects  the 
burning  efficiency  of  the  fireplace,  certain  guidelines  have 
been  set  in  I
NITIAL
  I
NSTALLATION
  -  V
ENT
  C
ONFIGURATIONS
 
AND
 
R
ESTRICTOR
 S
ETTINGS
.   
Venting terminals can not be recessed into 
a wall or siding.
WARNING:  This  gas  appliance  must 
not  be  connected  to  a  chimney  flue 
serving  a  separate  solid-burning 
appliances.
17