Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENT
 C
ONFIGURATIONS
 
AND
 R
ESTRICTOR
 S
ETTINGS
:
Figures 20 shows the range of venting options, it shows possible vent configurations if the unit is top 
vented,  for  vertical  and  horizontal  terminations,  any  layout  that  remains  within  the  shaded  area  is 
acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 
45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a 
longer one.
The vent restrictor controls the amount of air 
moving through the vent pipe. Longer vertical 
vent  lengths  necessitate  greater  restriction; 
position 1 is open and position 5 is maximum 
restriction. Figure 20 shows the vent restrictor 
settings required, relative to the length of vent 
pipe. The vent restrictor is located on the right 
side  of  the  fireplace,  above  the  glass.  Figure 
21  shows  the  vent  restrictor  handle  and  the 
holes that indicate the different levels. To avoid 
injury, it is best to make this adjustment when 
the fireplace is cool or use welder’s gloves or 
oven mitts.
Note: 0,0 in Figure 20 represents a 90˚ bend 
directly off the outlet of the unit, 46” (1169 mm) 
from  floor.  This  is  for  all  horizontal  instances 
except  when  using  Selkirk  and  having  less 
than a 4 feet (1.22 m) rise and 8 feet (2.44 m) 
horizontal offset. In this case, a 1 foot rise must 
be added below the 90˚ bend.