Operating Instructions
B
URNER
 L
IGHTING
:
A)  Make sure the pilot is lit.
B)  Turn gas control knob COUNTER CLOCKWISE to ON.
C)  Flip the burner switch to ON.
D) Turn HI/LO knob to the desired flame height.
E)  Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF
Flip switch to OFF to turn off burners only.
If  the  fireplace  is  to  be  turned  off  for  the  season,  or  for 
servicing,  turn  the  gas  shut  off  valve  to  OFF.    DO  NOT 
FORCE IT. If the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for 
the first four (4) hours. This will cure the paint, logs, gasket material, and other products used in the 
manufacturing process. It is advised that a door or window be opened as the unit will start to smoke, 
which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including 
the  pilot,  and  let  the  unit  get  completely  cold.  Then  remove  the  glass  and  clean  it  with  a  good  gas 
fireplace glass cleaner, available at your local Enviro dealer. See M
AINTENANCE
 A
ND
 S
ERVICE
 - C
LEANING
 T
HE
 
G
LASS
 and M
AINTENANCE
 A
ND
 S
ERVICE
 - G
LASS
 D
OOR
 R
EMOVAL
.
R
EMOTE
 C
ONTROLS
:
This fireplace can use an optional remote control or an optional cordless wall thermostat.  If either of 
these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the 
control panel) in the remote/thermostat position.  Consult the instructions included with the remote/wall 
thermostat for operation guidelines.
A
IR
 D
IVERTER
 C
ONTROL
:
When the blower is on, the amount of air flow into the room can be adjusted 
with the air diverter. When the lever is  to the far left the room receives the 
air, when the lever is  to the far right the air goes out the duct and when 
the lever in the middle the air goes to both the duct and the room. Lever is 
found above the right end of the control panel, see Figure 6.
B
LOWER
 S
PEED
:
The blower will come on only when the fireplace is up to temperature (approximately 
20 minutes).  The speed of the fan can be changed by turning the fan control knob.  
To  turn  the  blower  off,  turn  the  knob  COUNTER  CLOCKWISE  until  it  “clicks”  off   
(Figure 7). 
It is advisable not to operate the blower below 
1
/
3
 speed as it puts a strain on the 
windings of the blower and running the blower at lower speeds could also cause 
premature fan failure.
Figure 5.  Control Panel
Figure 7. Fan 
Control
Figure 6. Air Diverter
��
���
��
8