OPERATINg APPLIANCE
Continued 
5.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety information, page 10. If you don’t 
smell gas, go to the next step.
6.  Press in and turn control knob counter-
clockwise 
  to  the  PILOT  position. 
Press in control knob for five (5) seconds 
(see Figure 11). 
  Note: You may be running this appliance 
for the first time after hooking up to gas 
supply. If so, the control knob may need 
to be pressed in for 30 seconds or more. 
This will allow air to bleed from the gas 
system.
7.  With control knob pressed in, press and 
release ignitor button. This will light pilot. 
If needed, keep pressing ignitor button until 
pilot lights.
  Note: If pilot does not stay lit, contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure
8.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob.
• If control knob does not pop out when 
released, contact a qualified service person 
or gas supplier for repairs.
  Note: If pilot goes out, repeat steps 4 
through 8.
9.  Slightly push in and turn control knob coun-
terclockwise 
 to the ON position.
10.  Wait one minute and switch selector switch 
to the ON position to light burners. Note: 
AUTO is not functional.
Figure 11 - Control Knob and Ignitor Button
11.  Set flame adjustment knob to any level 
between HI and LO. Optional conversion 
kit only.
  Note: Unit is shipped from the factory with 
preset flame and manual on/off switch only 
(see Accessories on page 17 for complete list 
of accessories and conversion kits). 
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
  WARNING:  Make  sure  the 
selector  switch  is  in  the  OFF 
position  when  you  are  away 
from home for long periods of 
time. Appliance will come on au-
tomatically with selector switch 
in the ON position.
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Appliance
1.  Turn control knob clockwise  
  to 
the OFF position.
2a.  Set selector switch in the OFF position.
2b. 
If Using Optional Hand-Held Remote:
 Set se-
lector switch in the OFF position to prevent 
draining battery. 
Shutting Off Burner Only (pilot stays lit)
You may shut off the burners and keep the pilot 
lit by doing one of the following: 
1.  Turn control knob clockwise  
  to 
the PILOT position.
2.  Use remote control manual OFF button.
3.  Set selector switch in the OFF position.
MANUAL LIGHTING  
PROCEDURE
1.  Follow steps 1 through 6 under Lighting 
Instructions, page 10.
2.  Depress control knob and light pilot with 
match. 
3.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob. Now follow steps 9 through 
11 under Lighting Instructions.
Control Knob