TROUBLESHOOTINg
 WARNING: Turn off log set and let cool before servicing. Only a 
qualified service person should service and repair log set.
 CAUTION: Never use a wire, needle, or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note: 
All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
REMEDY
OBSERVED PROBLEM
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor  cable  pinched  or 
wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode positioned 
wrong or broken
1. Gas  supply  turned  off  or 
equipment  shutoff  valve 
closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Depleted  gas  supply  (pro-
pane/LP only)
6. Pilot is clogged
7. Gas regulator setting is not 
correct
When ignitor button is pressed, 
there is no spark at pilot
When ignitor button is pressed, 
there  is  spark  at  pilot  but  no 
ignition
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Tighten  nut  holding  piezo 
ignitor to base panel of log 
set. Nut is located behind base 
panel
4. Replace ignitor cable
5. Replace piezo ignitor 
6. Replace ignitor electrode 
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in 
PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP gas 
company
6. Clean pilot (see Cleaning and 
Maintenance,  page  12)  or 
replace pilot assembly
7. Replace gas regulator