TROUBLESHOOTINg
POSSIBLE CAUSE
REMEDY
OBSERVED PROBLEM
1. Control  knob  not  fully 
pressed in
2. Control knob not pressed in 
long enough
3. Safety  interlock  system 
has been triggered 
4. Equipment shutoff valve not 
fully open
5. Pilot  flame  not  touching 
thermocouple,  which  al-
lows thermocouple to cool, 
causing  pilot  flame  to  go 
out. This problem could be 
caused by one or both of the 
following:
  A) Low gas pressure
  B) Dirty or partially clogged 
pilot 
6. Thermocouple  connection 
loose at control valve 
7. Thermocouple damaged
8. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orifice clogged
3. Mislocated crossover tube
4. Remote  selector  in  OFF 
position
5. Wire disconnected from gas 
control
1. Manifold  pressure  is  too 
low
2. Burner orifice clogged
3. Mislocated crossover tube
1. Burner orifice is clogged or 
damaged
2. Damaged burner
3. Gas regulator defective
Pilot lights but flame goes out 
when control knob is released
One or both burner does not light 
after ODS/pilot is lit
Delayed ignition of burner
Burner backfiring during com-
bustion
1. Press in control knob fully
2. After pilot lights, keep control 
knob pressed in 30 seconds
3. Wait one minute for safety in-
terlock system to reset. Repeat 
ignition operation
4. Fully open equipment shutoff 
valve
5. A) Contact local natural or 
propane/LP gas company
 
  B) Clean pilot (see Cleaning 
and Maintenance, page 13) or 
replace pilot assembly 
6. Hand tighten until snug, then 
tighten 1/4 turn more
7. Replace pilot assembly
8. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning 
and Maintenance, page 12) 
or replace burner orifice
3. Contact  qualified  service 
person
4. Put  remote  selector  in  ON 
position
5. See Wiring Diagram, page 17
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning 
and Maintenance, page 12) 
or replace burner orifice
3. Contact  qualified  service 
person
1. Clean burner (see Cleaning 
and Maintenance, page 12) 
or replace burner orifice
2. Replace damaged burner
3. Replace gas regulator