Toshiba CEILING TYPE 用户手册

下载
页码 120
– 90 –
No.
4
Part name
Ceiling panel
Procedure
1. Detachment
1) Perform works of procedure  1  -1-,  2  -1,
and  3  -1.
2) Remove the flap connector (CN33, White, 5P)
connected to the control P.C. board and then
take off the lead wire from the clamp.
NOTE)
Remove the connectors after unlocking the lock of
the housing.
3) Take off screws (M5, 4 pcs.) fixing the ceiling
panel.
4) Push the temporary bracket to inner side to
remove the ceiling panel.
2. Attachment
1) Hook the panel to the temporary bracket of
the drain pan of the main body.
NOTE)
The panel has directionality.
Therefore mount the panel according to the temporary
bracket and the bracket mounting position.
2) Tighten the fixing screws. (M5, 4 pcs.)
3) Connect flap connector of the
ceiling panel to the connector
(CN33, White, 5P) of the
control P.C. board.
Hanging 
section of tentative 
hook of ceiling panel
Temporary 
bracket
Push to remove
Drain piping 
corner
Ceiling panel
Hanging section 
of temporary bracket
Washer 
based screw
Cable clamp
CN33
Temporary 
bracket
Remarks