boiler protection devices
Boiler protection devices
The boiler is protected from malfunctioning by means of internal 
checks performed by the electronic microprocessor P.C.B., which 
stops the boiler from operating if necessary.
In the event of the boiler being shut off  in this manner, a code 
appears on the display which refers to the type of shut-off  and the 
reason behind it.
There are two types of shut-off :
Safety shut-off  
This type of error is “volatile”, which 
means that the boiler starts up again 
automatically as soon as the prob-
lem which caused the shut-off  is re-
moved; the error is indicated by the 
«Err» symbol which appears on the 
display and the error code.
In fact, soon as the cause of the shut-
off  disappears, the boiler starts up 
again and continues to operate nor-
mally.
In the event of error 1 08 - Shut-off  
due to insuffi
  cient water pressure 
inside the heating circuit - the boiler 
will perform a safety shut-off .
You can increase the pressure by 
fi lling the heating circuit.
In this case or if the re-balancing 
request is performed on a frequent 
basis, switch the boiler off , turn the 
external electric switch to the OFF 
position, shut off  the gas cock and contact a qualifi ed technician 
to check for any leaks of water.
Shutdown
This type of error is “non-volatile”, which means that it is not 
removed automatically. To restore normal operation press the 
 button on the control panel.
Malfunction warning
This warning is shown by the display in the following format:  
5  P1 = FIRST IGNITION ATTEMPT UNSUCCESSFUL
the fi rst fi gure indicating the operational assembly is followed by 
a P (warning) and the code relating to the specifi c warning.
Important
If this shutdown occurs frequently, contact an authorised Technical 
Service Centre for assistance. For safety reasons, the boiler will 
permit a maximum of 5 resets in 15 minutes (5 presses of the 
RESET button); at the 6th attempt within this 15-minute period 
the boiler will shut down and may only be operated again after 
the electricity supply has been disconnected. If the shutdown is 
occasional or an isolated event, this is not a problem.
The fi rst fi gure of the error code (e.g. 1 01) indicates within which 
operational assembly the error occurred.
1 - Primary Circuit
2 - Domestic Hot Water Circuit
3 - Internal Electronic Part
4 - External Electronic Part
5 - Ignition and Detection
6 - Air inlet - fl ue gas outlet
7 - Multi-zone Heating
Table summarising error codes 
Central Heating circuit
Display
Description
1 01
Overheat
1 02
Pressure Sens Error
1 03
Insuffi
  cient circulation
1 04
1 05
1 06
1 07
1 08
Insuffi
  cient water (request fi lling)
1 10
C.H. Flow temp. probe circuit open / short circuit
1 12
C.H. Return temp. probe circuit open / short circuit
1 14
External sensor circuit open / short circuit
1 16
Floor Thermostat contact open
1 18
Heating delevery probe problem
1 P1
Insuffi
  cient circulation indication
1 P2
1 P3
D.H.W. circuit
2 02
Bottom storage temperature probe open / 
short circuit
S
olar k
it
(optional)
2 04
Solar collector temperature probe open / 
short circuit
2 07
Solar collector overheating
2 08
Collector frost protection temperature
Internal P.C.B.’s
3 01
EEPROM error
3 02
Comunication error
3 03
Main P.C.B. error
3 04
Too many (> 5) resets in 15 minutes
3 05
Main P.C.B. error
3 06
Main P.C.B. error
3 07
Main P.C.B. error
External P.C.B.’s
4 07
Room sensor circuit open/short circuit
Ignition and Detecion
5 01
No fl ame detected
5 02
 Flame detected with gas valve closed
5 04
Flame lift
5 P1
1st Ignition Failed
5 P2
2nd Ignition Failed
5 P3
Flame cut-off 
Air Inlet / Flue gas outlet
6 04
Insuffi
  cient fan speed
6 10
 Thermofuse  open