11
INSTALLATION
FACTORY
BUILT CHIMNEY
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the 
ceiling support package or wall pass-through and "T" section package, fi restops (where needed), insulation shield, roof fl ashing, chimney cap, etc. 
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other 
obstructions for safety and proper draft operation.
MASONRY
CHIMNEY
Ensure that a masonry chimney meets the mini-
mum standards of the National Fire Protection 
Association (NFPA) by having it inspected by 
a professional. Make sure there are no cracks, 
loose mortar or other signs of deterioration and 
blockage. Have the chimney cleaned before 
the stove is installed and operated. When 
connecting the stove through a combustible 
wall to a masonry chimney, special methods 
are needed.
MASONRY
FIREPLACE
There are listed kits available to connect a stove 
to a masonry fi replace. The kit is an adapter 
that is installed at the location of the fi replace 
damper. The existing damper may have to be 
removed to allow installation.