Regency FG39 FireGenie Freestanding Gas Stove
INSTALLATION
DV  STOVE  HORIZONTAL  FLUE  KIT  (#946-112)  INSTALLATION
Minimum 
Installation 
Height:
FG39: 59-3/4" ( 1518mm)
Review  the  following  sequence  of  instruc-
tions which are typical of most installations.
The  sequence  may  vary  depending  on  wall
thickness. Refer to  flue location and clear-
ance  dimensions  on  pages  8  to  9.
1) Set the unit in its desired location. Check
to determine if wall studs will be in the way
of the fluing system, adjust location until all
clearances  are  met  and  there  are  no
obstructions.
Note: A  1-1/2"(38mm)  clearance  around
the  outer  pipe  must  be  main-
tained  except  that  only  a  1"
(25mm)  clearance  is  needed  at
the  termination  end.
IMPORTANT:
Do  not  locate  termination  hood  where
excessive  snow  or  ice  buildup  may  oc-
cur.  Be  sure  to  check  flue  termination
area  after  snow  falls,  and  clear  to  pre-
vent  accidental  blockage  of  fluing  sys-
tem.  When  using  snow  blowers,  make
sure  snow  is  not  directed  towards  flue
termination  area.
2) Assemble a trial fit to determine the ver-
tical center-line for the flue termination.
a) Cut a  241mm round hole on both the
interior and exterior wall.
b) Attach the 2 ft. (.6m) pipe section to
the flue terminal and slide into posi-
tion  from  the  exterior.  The  larger
diameter  end  of  the  adjustable
pipe  goes  to  the  flue  terminal.
c) Install the 90
o
 elbow onto the adjust-
able  pipe  to  determine  the  vertical
centerline of the starter collar on the
unit.
Note: if the centerline cannot be
met, the adjustable sections will
have  to  be  cut.
DV  STOVE  HORIZONTAL  FLUE  KIT
Horizontal  Stove  Flue  Kit  (Part  #  946-112)  includes  all  the  parts  needed  to  install  the  FG39
Freestanding Gas unit with  minimum horizontal and vertical vent dimensions. For installations that
require longer vertical and/or horizontal vents use the Dura-Vent system as shown in your manual.
    Qty.
Description
1)
2 Rigid Pipe Section 1.2m length,  165mm inside diameter
2)
1 Flex Liner, compressed aluminium 2 ply liner, 102mm inside diameter
3)
4 spring  spacers
4)
1 90 deg. Elbow
5)
1 Decorative Wall Trim
6)
1 Adapter
7)
AstroCap Termination Cap
8)
2 Trim Collar
9)
1 tube of Mill-Pac, high temperature sealant
10) 12 Screws, #8 x 1/2" (13mm) Self tapping, Stainless Steel
11) 14 Screws, #8 x 1/2" (13mm) Self tapping, Black
12)
4 Screws #8 x 1-1/2" (38mm) Drill Point, Stainless Steel
Optional:
946-206 Vinyl  Siding  Standoff  for  AstroCap
Note:
a ) Liner  sections  should  be  continuous
without  any  joints  or  seams.
b) This  is  an  approved  system,  therefore
components in this system must not be
substituted  for  any  other  manufactur-
er's  products.
c) Wall  Thimble  is  required  when  install-
ing  through  a  combustible  wall.