INSTALLATION
FLUEING  ARRANGEMENTS
Vertical Terminations Using
Dura-Flue Fluing System for
Residential Manufactured and Mobile Homes
The  shaded  area  in  the  diagram  below  shows  all  allowable
combinations  of  straight  vertical  and  offset  to  vertical  runs
with  vertical  terminations.  Maximum  two  45
o
  elbows.
If the flue is ENCLOSED in a chase (min. size 9" x 9" / 229mm x 229mm)
maintain a 1-1/4" (32mm) clearance to combustibles.
May  be  installed  in  Manufactured  (Mobile)  Homes  after  first  sale.
Horizontal Terminations for All Fluing Systems
The  shaded  areas  in  the  diagram  below  show  all  allowable
combinations  of  vertical  runs  with  horizontal  terminations.
Maximum one 90
O
 elbow (two  45
elbows equal one 90
o
 elbow).
LPG and NG:
Residential, Manufactured and Mobile Homes
Installations
The fluing arrangements diagrammed below, have a min. of 75% (flue
loss)  efficiency  with  Fan  Off,  as  required  for  manufactured  homes.
(Actual efficiency may be as high as 85%)
May  be  installed  in  Manufactured  (Mobile)  Homes  after  first  sale.
Flue Restrictor Position
To set the Flue restriction as indicated in the diagram, simply loosen the
screws and push the flue restrictor plate to the correct position. Tighten
the  screws.
Flue  Restrictor  setting  at
40 Mj/h
Flue  Restrictor  setting  at
31 Mj/h